MX-3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 – 23
14. Fuses and Thermostats
Signal name
Name
100v series
200v series
Section
F1
Fuse
20A 250V
T10AH 250V
AC Power PWB
F2
Fuse
-
T10AH 250V
AC Power PWB
F001
Fuse
T12AH 250V
T6.3AH 250V
DC Power PWB
F003
Fuse
T3.15AH 250V
T3.15AH 250V
DC Power PWB
F101
Fuse
F10AH 250V (F101)
F5AH 250V (F101)
DC Power PWB
F401
Fuse
F3.15AH 250V (F401)
F2AH 250V (F401)
DC Power PWB
F201
Fuse
6.3A
6.3A
DC Power PWB
F202
Fuse
6.3A
6.3A
DC Power PWB
F203
Fuse
6.3A
6.3A
DC Power PWB
F204
Fuse
6.3A
6.3A
DC Power PWB
F205
Fuse
4.0A
4.0A
DC Power PWB
Signal name
Name
Type
Function/Operation
TS LM
Thermostat LM
Mechanical thermostat
Shuts down the heater lamp (HL_LM) circuit when the fusing section is overheated.
TS UM
Thermostat UM
Mechanical thermostat
Shuts down the heater lamp (HL_UM) circuit when the fusing section is overheated.
(Center section)
TS US
Thermostat US
Mechanical thermostat
Shuts down the heater lamp (HL_US) circuit when the fusing section is overheated.
(Edge section)
43,-
43?5-
&
&
&
&
&
&
&
&
&
&
&
43?53
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...