MX-3114N ADJUSTMENTS AND SETTINGS 5 – 22
4)
Make a normal copy on A4 paper.
Go to the copy mode, and make a copy.
5)
Compare the copied image of the scale and the actual scale
length in terms of length.
6)
Obtain the copy magnification ratio correction ratio in the main
scanning direction from the following formula.
Main scanning direction copy magnification ratio correction
ratio = (Original size - Copy image size) / Original size x 100%
(Example)
Compare the scale of 10mm with the scale of 10mm on the
copy image.
Main scanning direction copy magnification ratio correction
ratio = (100 - 99) / 100 x 100 = 1
If the copy magnification ratio is not satisfactory, perform the
following procedures.
7)
Remove the document table glass.
8)
Remove the dark box cover.
9)
To prevent against shift of the CCD unit optical axis, mark the
CCD unit base as shown below.
This procedure must be executed also when the CCD unit is
replaced.
10) Loosen the CCD unit fixing screws.
Never loosen the screws marked with X.
If any one of these screws is loosened, the position and the
angle of the CCD unit base may be changed to cause a prob-
lem, which cannot be adjusted in the market. In that case, the
whole scanner unit must be replaced.
11) Slide the CCD unit in the arrow direction (CCD sub scanning
direction) to change the installing position.
When the copy image is longer than the original scale, shift the
CCD unit in the direction B. When the copy image is shorter
than the original scale, shift the CCD unit in the direction A.
One scale of mark-off line corresponds to 0.2%.
At that time, fix the CCD unit so that it is in parallel with the
scale on the front and the rear side of the CCD unit base.
* Fix the CCD unit so that it is in parallel with the line marked
in procedure 9).
12) Make a copy and check the copy magnification ratio again.
If the copy magnification ratio is not in the range of 100
1%,
repeat the procedures of 9) - 11) until the condition is satisfied.
By changing the CCD unit fixing position with the simulation 48-1
adjustment value at 50, the copy magnification ratio is adjusted
within the specified range (100
1.0%) and the specified resolution
is obtained based on the optical system structure.
10
20
90
100
110
10
20
90
100
110
1.0mm
100mm scale
(Orignal)
Copy image
(1mm (1%)
shorter than
the original)
A
B
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...