MX-3114N SIMULATION 6 – 16
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simulta-
neously.
Section
Process (Charging)
Operation/Procedure
1)
Select a speed with [MIDDLE] and [LOW] keys on the touch
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the adjustment value with 10-key. (The value specified
on the label of the high voltage PWB must be entered.)
* When the
key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the transport voltage and the control circuit.
Section
Process (Transport)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
Enter the default value specified on the following list.
3)
Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display (Mode)
Content
Adjustment
range
Actual voltage
MIDDLE
A
MIDDLE SPEED GB_K
Main charger grid voltage (Middle speed mode)
K
150 - 850
–620V
5V
B
MIDDLE SPEED GB_C
Main charger grid voltage (Middle speed mode)
C
150 - 850
–620V
5V
C
MIDDLE SPEED GB_M
Main charger grid voltage (Middle speed mode)
M
150 - 850
–620V
5V
D
MIDDLE SPEED GB_Y
Main charger grid voltage (Middle speed mode)
Y
150 - 850
–620V
5V
LOW
A
LOW SPEED GB_K
Main charger grid voltage (Low speed mode)
K
150 - 850
–610V
5V
B
LOW SPEED GB_C
Main charger grid voltage (Low speed mode)
C
150 - 850
–590V
5V
C
LOW SPEED GB_M
Main charger grid voltage (Low speed mode)
M
150 - 850
–590V
5V
D
LOW SPEED GB_Y
Main charger grid voltage (Low speed mode)
Y
150 - 850
–590V
5V
Item/Display
Content
Setting
value
Default value
23cpm
26cpm/31cpm
A
TC1 LOW SPEED CL K
Primary transfer bias
adjustment value
Color
K
Low speed
51 - 255
80
80
B
TC1 MIDDLE SPEED CL K
Middle
speed
51 - 255
95
109
C
TC1 LOW SPEED CL C
C
Low speed
51 -255
80
80
D
TC1 MIDDLE SPEED CL C
Middle
speed
51 - 255
95
109
E
TC1 LOW SPEED CL M
M
Low speed
51 - 255
80
80
F
TC1 MIDDLE SPEED CL M
Middle
speed
51 - 255
95
109
G
TC1 LOW SPEED CL Y
Y
Low speed
51 - 255
80
80
H
TC1 MIDDLE SPEED CL Y
Middle
speed
51 - 255
95
109
I
TC1 LOW SPEED BW K
Black/
White
K
Low speed
51 - 255
80
80
J
TC1 MIDDLE SPEED BW K
Middle
speed
51 - 255
95
109
K
TC2 PLAIN CL SPX
Secondary transfer bias
adjustment value
Color
Plain
paper
Front
surface
51 - 255
96
103
L
TC2 PLAIN CL DPX
Back
surface
51 - 255
76
90
M
TC2 PLAIN BW SPX
Black/
White
Front
surface
51 - 255
96
103
N
TC2 PLAIN BW DPX
Back
surface
51 - 255
76
90
O
TC2 HEAVY CL SPX
Color
Heavy
paper
Front
surface
51 - 255
83
83
P
TC2 HEAVY CL DPX
Back
surface
51 - 255
76
76
Q
TC2 HEAVY BW SPX
Black/
White
Front
surface
51 - 255
69
69
R
TC2 HEAVY BW DPX
Back
surface
51 - 255
69
69
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...