MX-3114N SIMULATION 6 – 95
53
53-6
Purpose
Adjustment
Function (Purpose)
Used to adjust the detection level of the
RSPF document width.
Section
Operation/Procedure
1)
Open the RSPF paper feed guide to the maximum width.
2)
Press [EXECUTE] key.
The maximum width detection level is recognized.
3)
Open the RSPF paper feed guide to the A4R width.
4)
Press [EXECUTE] key.
The A4R width detection level is recognized.
5)
Open the RSPF paper feed guide to the A5R width.
6)
Press [EXECUTE] key.
The A5R width detection level is recognized.
7)
Open the RSPF paper feed guide to the minimum width.
8)
Press [EXECUTE] key.
The minimum width detection level is recognized.
When the above operation is nor performed normally, "ERROR" is
displayed and. When the above operation is completed normally,
"COMPLETE" is displayed.
53-7
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the RSPF document size
width sensor.
Section
Operation/Procedure
1)
Select an adjustment target item with scroll key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
[RSPF]
53-8
Purpose
Adjustment
Function (Purpose)
Used to adjust the document lead edge ref-
erence and the RSPF mode document
scan position.
Section
Operation/Procedure
Select an adjustment item with [AUTO] [MANUAL] key.
<AUTO: Document lead edge reference (RRCA) adjustment>(Auto
adjustment)
1)
Set a sheet of black paper of A4 or 11"x 8.5" on the document
table.
2)
Press [EXECUTE] key. (The adjustment is performed and the
adjustment value is saved.)
<MANUAL: RSPF mode document scan position adjustment>
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
• When the adjustment value is increased, the scanner stop posi-
tion in the RSPF mode is shifted to the right.
• When the adjustment value is changed by 1, the position is
shifted by 0.1mm.
1
TRAYVOLMAX
Tray size volume maximum value
2
TRAYVOLA4R
Tray volume A4R size adjustment value
3
TRAYVOLA5R
Tray volume A5R size adjustment value
4
TRAYVOLMIN
Tray size volume minimum value
Item/Display
Setting
range
Default
value
A
AD_MAX
Max. width position
0 - 1023
84
B
AD_P1
A4R width position
0 - 1023
509
C
AD_P2
A5R width position
0 - 1023
808
D
AD_MIN
Min. width position
0 - 1023
961
Item/Display
Content
Setting
range
Default
value
MEASUREMENT
DISTANCE
Document lead edge
measurement distance
0-255
(0.1mm unit)
-
RRCA
Document lead edge
reference position
0 - 99
50
Item/Display
Content
Setting
range
Default
value
A
ADJUST
VALUE
RSPF mode document scan
position adjustment (Scanner
stop position adjustment)
1 - 99
5
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...