MX-3114N SIMULATION 6 – 29
25
25-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the devel-
oping section.
Section
Process (Developing section)
Operation/Procedure
1)
Select the process speed with [MIDDLE], [LOW] keys.
2)
Press [EXECUTE] key.
The developing motor and the OPC drum motor rotate for 3
minutes and the output level of the toner density sensor is dis-
played.
The toner cartridge must be removed before executing this simula-
tion.
If this simulation is executed with the toner cartridge installed, toner
will be forcibly supplied to the developing unit, resulting in over-
toner and a trouble.
25-2
Purpose
Setting
Function (Purpose)
Used to make the initial setting of toner
density when replacing developer. (Auto-
matic adjustment)
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1)
Select a color to be adjusted with the touch panel.
2)
Press [EXECUTE] key.
The developing motor rotates for 1 min 30 sec, and the toner den-
sity sensor makes sampling of the toner density. The detected level
is displayed.
After stopping the developing motor, the average value of the toner
density sampling results is set as the reference toner density con-
trol level.
When the above operation is interrupted on the way, the reference
toner concentration level is not set. Also when error code of EE-EC,
EE-EL or EE-EU is displayed, the reference toner density level is
not set normally.
Do not execute this simulation except when new developer is sup-
plied. If it is executed in other cases, undertoner or overtone may
occur, causing a trouble.
Display during execution of the simulation
Error content
25-4
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the operation data of the
toner supply quantity. (Not used in the mar-
ket.)
Section
Process
Operation/Procedure
The operation data of the toner supply quantity are displayed.
TCS_K
Toner sensor output value (K)
TCS_C
Toner sensor output value (C)
TCS_M
Toner sensor output value (M)
TCS_Y
Toner sensor output value (Y)
TSG_K
Toner density sensor control voltage level (K)
TSG_C
Toner density sensor control voltage level (C)
TSG_M
Toner density sensor control voltage level (M)
TSG_Y
Toner density sensor control voltage level (Y)
LOW
Process speed: Low speed
MIDDLE
Process speed: Medium speed
Division
Item/Display
Display
range
Default
value
Toner density control
adjustment value in the
low speed process mode
AT DEVE ADJ_L_K
1 - 255
128
AT DEVE ADJ_L_C
1 - 255
128
AT DEVE ADJ_L_M
1 - 255
128
AT DEVE ADJ_L_Y
1 - 255
128
Toner density control
adjustment value in the
medium speed process
mode
AT DEVE ADJ_M_K
1 - 255
128
AT DEVE ADJ_M_C
1 - 255
128
AT DEVE ADJ_M_M
1 - 255
128
AT DEVE ADJ_M_Y
1 - 255
128
Toner density sensor
control voltage level in
the low speed process
mode
AT DEVE VO_L_K
1 - 255
128
AT DEVE VO_L_C
1 - 255
128
AT DEVE VO_L_M
1 - 255
128
AT DEVE VO_L_Y
1 - 255
128
Toner density sensor
control voltage level in
the medium speed
process mode
AT DEVE VO_M_K
1 - 255
128
AT DEVE VO_M_C
1 - 255
128
AT DEVE VO_M_M
1 - 255
128
AT DEVE VO_M_Y
1 - 255
128
Item/Display
Content
TCS_K
Toner sensor output value (K)
TCS_C
Toner sensor output value (C)
TCS_M
Toner sensor output value (M)
TCS_Y
Toner sensor output value (Y)
TSG_K
Toner density sensor control voltage level (K)
TSG_C
Toner density sensor control voltage level (C)
TSG_M
Toner density sensor control voltage level (M)
TSG_Y
Toner density sensor control voltage level (Y)
Display
Error name
Error content
EE-EL
EL abnormality
The sensor output level is less than 77, or
the control voltage exceeds 207.
EE-EU
EU abnormality
The sensor output level exceeds 177, or the
control voltage is less than 52.
EE-EC
EC abnormality
The sensor output level is outside of 128±3.
Item/Display
Content
Display
range
YLD_CNT_FB
Toner supply FB rate by the yield
count
50 - 200
DELTA_DVB
Delta DVB (Process control DVB -
Target DVB)
-500 - 500
IDL_DVB
Target DBV
100 - 600
PROCON_DVB
Process control DVB
100 - 600
DV_LIFE
Developer life area
1 - 8
COVERAGE_
AREA
Average print rate area
1 - 10
ENV_AREA
Environment area
1 - 8
MULTI_TIME
Toner supply drive time area
(Specified by the DV motor rotation
time)
1 - 8
PRO_FB_CNT
No. of remaining times of toner supply
for the process control result
0 - 65535
PRO_FB_INT
Interval of toner supply for the
process control result
0 - 65535
PRO_FB_RATIO
Correction rate of one-time toner
supply for the process control result
-10 -10
RECV_MODE_
CNT(+)
No. of times of recovery mode (+)
(No. of times of compulsory toner
supply)
0 - 65535
RECV_MODE_
CNT(-)
No. of times of recovery mode (-) (No.
of times of compulsory printing of
one-color background image)
0 - 65535
Division
Item/Display
Display
range
Default
value
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...