MX-3114N SIMULATION 6 – 48
43-20
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-2) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Correction value: -49 - +49, Input value: Actually inputted value (1 -
99)
* Item WARMUP END TIME LL: 1 Count = 1s Change
Correction value for the other items: 1 count for 1
C change
* Item D, F: When B5 size, correction of "-5" is made for item D and item F.
* Item G, I: When B5 size, correction of "-5" is made for item G and item I.
Code descriptions
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting
range
Default
value
A
HL_UM READY LL
Correction value for TH_UM set value in Ready standby under LL environment
1 - 99
55
B
HL_LM READY LL
Correction value for TH_LM set value in Ready standby under LL environment
1 - 99
55
C
HL_US READY LL
Correction value for TH_US set value in Ready standby under LL environment
1 - 99
55
D
HL_UM PLAIN BW LL
Correction value for Black-White plain paper TH_UM set value under LL environment
1 - 99
55
E
HL_LM PLAIN BW LL
Correction value for Black-White plain paper TH_LM set value under LL environment
1 - 99
55
F
HL_US PLAIN BW LL
Correction value for Black-White plain paper TH_US set value under LL environment
1 - 99
55
G
HL_UM PLAIN CL LL
Correction value for Color plain paper TH_UM set value under LL environment
1 - 99
55
H
HL_LM PLAIN CL LL
Correction value for Color plain paper TH_LM set value under LL environment
1 - 99
55
I
HL_US PLAIN CL LL
Correction value for Color plain paper TH_US set value under LL environment
1 - 99
55
J
WARMUP FUMON HL_US T LL
Correction value for fusing motor pre-rotation start TH_US set value under LL environment
1 - 99
55
K
WARMUP FUMOFF LL
Fusing motor prior rotation completion time under LL environment
1 - 99
55
L
WARMUP END TIME LL
Correction value for warm-up complete time under LL environment
1 - 99
55
M
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under LL environment
1 - 99
55
N
HL_LM HEAVY LL
Correction value for heavy paper TH_LM set value under LL environment
1 - 99
55
O
HL_US HEAVY LL
Correction value for heavy paper TH_US set value under LL environment
1 - 99
55
P
HL_UM OHP LL
Correction value for OHP TH_UM set value under LL environment
1 - 99
55
Q
HL_LM OHP LL
Correction value for OHP TH_LM set value under LL environment
1 - 99
55
R
HL_US OHP LL
Correction value for OHP TH_US set value under LL environment
1 - 99
55
S
HL_UM ENVELOPE LL
Correction value for envelope TH_UM set value under LL environment
1 - 99
55
T
HL_LM ENVELOPE LL
Correction value for envelope TH_LM set value under LL environment
1 - 99
55
U
HL_US ENVELOPE LL
Correction value for envelope TH_US set value under LL environment
1 - 99
55
V
HL_UM GLOSS LL
Correction value for glossy paper TH_UM set value under LL environment
1 - 99
55
W
HL_LM GLOSS LL
Correction value for glossy paper TH_LM set value under LL environment
1 - 99
55
X
HL_US GLOSS LL
Correction value for glossy paper TH_US set value under LL environment
1 - 99
55
Y
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL environment
1 - 99
55
Z
HL_US E-STAR LL
Correction value for preheating TH_US set value under LL environment
1 - 99
55
AA
HL_UM PRE-JOB LL
Correction value for the set value of TH_UM when restoring from preheating under LL
environment
1 - 99
55
AB
HL_LM E-STAR LL
Correction value for preheating TH_LM set value under LL environment
1 - 99
55
AC
LO_WARMUP_TIME_LL
Correction value for AF-AH applying time (timer from Ready complete) under LL environment
1 - 99
50
AD
HI_WU_TIME_LL
Correction value for AJ-AL applying time (timer from Ready complete) under LL environment
1 - 99
50
AE
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha
C or above under LL
environment
1 - 99
40
AF
HI_WU_END_TIME_LL
Correction value for Warm-Up completion time in Warm-Up at alpha
C or above under LL
environment
1 - 99
50
AG
HI_WU_JOB_SET_TMP_LL
Correction value for Job Enable TH_UM temperature in at alpha
C or above under LL
environment
1 - 99
55
AH
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying SIM43-1-AN - AP under LL
environment
1 - 99
50
AI
LO_WU_JOB_SET_TMP_LL
Correction value for Job Enable TH_UM temperature in at alpha
C or below under LL
environment
1 - 99
55
AJ
JOBEND_FUMON_TIME LL
Correction value for the after rotation time when completing a job under LL environment
1 - 99
50
AK
LO_WU_JOB_SET_TMP_BW LL
Correction value (BW) for Job enable TH_UM temperature when Warm-Up at
alpha
C
or above under LL environment
1 - 99
55
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_LM
Fusing thermistor main (Back surface of paper)
HL_LM
Heater lamp main (Heat roller for back surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...