MX3114N TROUBLESHOOTING 7 – 15
F2-22
Discharge lamp trouble (K)
F2-23
Discharge lamp trouble (C)
F2-24
Discharge lamp trouble (M)
F2-25
Discharge lamp trouble (Y)
F2-39
Process thermistor trouble
F2-40
Toner density sensor trouble (K)
F2-41
Toner density sensor trouble (C)
F2-42
Toner density sensor trouble (M)
F2-43
Toner density sensor trouble (Y)
Trouble content
The lamp is kept open for 1 sec from turning on the
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB (K)
and the PCU PWB.
Discharge lamp PWB (K) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (K).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
The lamp is kept open for 1 sec from turning on the
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB (C)
and the PCU PWB.
Discharge lamp PWB (C) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (C).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
The lamp is kept open for 1 sec from turning on the
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB
(M) and the PCU PWB.
Discharge lamp PWB (M) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (M).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
The lamp is kept open for 1 sec from turning on the
discharge lamp.
Detail
PCU
Cause
Contact trouble between the discharge lamp PWB (Y)
and the PCU PWB.
Discharge lamp PWB (Y) trouble.
PCU PWB trouble.
Check & Remedy
Replace the discharge lamp PWB (Y).
Check the harness and the connector.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Process thermistor trouble.
Process thermistor harness connection trouble.
PCU PWB trouble.
Check & Remedy
Replace the process thermistor.
Check connection of the process thermistor harness
and the connector.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Toner density sensor output abnormality.
Sensor connector and harness connection trouble.
Developing unit trouble.
PCU PWB trouble.
Check & Remedy
Replace the toner density sensor.
Check connection of the sensor connector and the
harness.
Replace the developing unit.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Toner density sensor output abnormality.
Sensor connector and harness connection trouble.
Developing unit trouble.
PCU PWB trouble.
Check & Remedy
Replace the toner density sensor.
Check connection of the sensor connector and the
harness.
Replace the developing unit.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Toner density sensor output abnormality.
Sensor connector and harness connection trouble.
Developing unit trouble.
PCU PWB trouble.
Check & Remedy
Replace the toner density sensor.
Check connection of the sensor connector and the
harness.
Replace the developing unit.
Replace the PCU PWB.
Trouble content
Detail
PCU
Cause
Toner density sensor output abnormality.
Sensor connector and harness connection trouble.
Developing unit trouble.
PCU PWB trouble.
Check & Remedy
Replace the toner density sensor.
Check connection of the sensor connector and the
harness.
Replace the developing unit.
Replace the PCU PWB.
Содержание MX-2314N
Страница 47: ...MX 3114N EXTERNAL VIEW AND INTERNAL STRUCTURE 4 21 13 PWB Memory device CPM CPM MACHINE CPM MACHINE ...
Страница 317: ...MX 3114N MAINTENANCE 9 18 11 11 1 6 3 9 10 15 7 8 12 2 4 5 14 ...
Страница 319: ...MX 3114N MAINTENANCE 9 20 1 2 5 5 7 3 6 10 11 8 3 4 2 4 9 ...
Страница 323: ...MX 3114N MAINTENANCE 9 24 2 11 11 13 10 12 3 14 5 6 14 4 7 9 8 1 ...
Страница 335: ...MX 3114N MAINTENANCE 9 36 1 3 20 18 15 15 17 24 19 16 2 4 7 11 24 20 5 22 6 9 12 14 13 10 13 14 23 23 21 6 8 9 12 ...
Страница 337: ...MX 3114N MAINTENANCE 9 38 23 23 1 2 21 21 22 7 6 5 16 8 9 10 13 14 15 24 3 19 16 18 20 17 12 14 10 13 15 11 4 5 4 24 ...
Страница 342: ...MX 3114N MAINTENANCE 9 43 21 23 24 1 6 2 3 5 6 22 24 22 22 6 25 23 4 7 13 8 9 13 12 10 11 14 20 15 16 20 19 17 18 ...
Страница 344: ...MX 3114N MAINTENANCE 9 45 ...