MX-2300/2700 N/G ADJUSTMENTS 6 – 43
Normally individual adjustments are not required. This adjustment
is executed when there is a request from the user.
1)
Enter the SIM 46-10 mode.
2)
Select the copy mode to be adjusted with the mode key.
3)
Select a color to change the adjustment value with the color
key.
4)
Select the density level (point) to be adjusted with the scroll
key.
5)
Enter the adjustment value with 10-key and press [OK] key.
When the adjustment value is increased, the density is
increased. When the adjustment value is decreased, the den-
sity is decreased.
When the arrow key is pressed, the color densities selected
with the color keys are collectively adjusted. That is, all the
density levels (points) from the low density point to the high
density point can be adjusted collectively.
When [EXECUTE] key is pressed, the adjustment pattern is
printed out.
The color balance at each density level (point) and the density
can be checked by referring to this printed adjustment pattern.
However, it is more practically to make a cop and check it.
20-G Monochrome copy density adjustment
(Density adjustment at each density level in
each monochrome copy mode) (Normally
not required)
This adjustment is required in the following cases.
* When a U2 trouble occurs.
* When the MFP PWB is replaced.
* When the EEPROM on the MFP PWB is replaced.
This is to adjust each density level in each monochrome copy
mode.
Normally individual adjustments are not required. This adjustment
is executed when there is a request from the user.
1)
Enter the SIM 46-16 mode.
2)
Select the density level (point) to be adjusted with the scroll
key.
3)
Enter the adjustment value with 10-key and press [OK] key.
When the adjustment value is increased, the density is
increased. When the adjustment value is decreased, the den-
sity is decreased.
When the arrow key is pressed, the selected are collectively
adjusted. That is, all the density levels (points) from the low
density point to the high density point can be adjusted collec-
tively.
When [EXECUTE] key is pressed, the adjustment pattern is
printed out.
The density at each density level (point) can be checked by
referring to this printed adjustment pattern. However, it is more
practically to make a cop and check it.
Item/Display
Density level
(Point)
Adjustment
value range
Default value
A
POINT1
Point 1
245 – 755
500
B
POINT2
Point 2
245 – 755
500
C
POINT3
Point 3
245 – 755
500
D
POINT4
Point 4
245 – 755
500
E
POINT5
Point 5
245 – 755
500
F
POINT6
Point 6
245 – 755
500
G
POINT7
Point 7
245 – 755
500
H
POINT8
Point 8
245 – 755
500
I
POINT9
Point 9
245 – 755
500
J
POINT10
Point 10
245 – 755
500
K
POINT11
Point 11
245 – 755
500
L
POINT12
Point 12
245 – 755
500
M
POINT13
Point 13
245 – 755
500
N
POINT14
Point 14
245 – 755
500
O
POINT15
Point 15
245 – 755
500
OK
EXECUTE
C
EXECUTE
SIMULATION
NO.46-10
TEST
ENGINE COLOR BALANCE MANUAL ADJUSTMENT
1/1
0
TEXT
TEXT / PRT
PHOTO
PRINTED PHOTO
PHOTO+TEXT/PHOTO
CLOSE
MAP
LIGHT
COPY ORG
A:
A
㧦
xxx
B
㧦
xxx
C
㧦
xxx
D
㧦
xxx
㧧
POINT 1
㧧
POINT 2
㧧
POINT 3
㧧
POINT 4
SIMULATION
NO. 46-10
ENGINE COLOR BALANCE MANUAL ADJUSTMENT [TXST]
xxx
245
755
OK
TEST
K
C
M
Y
0
EXECUTE
CLOSE
A:
A
㧦
xxx
B
㧦
xxx
C
㧦
xxx
D
㧦
xxx
㧧
POINT 1
㧧
POINT 2
㧧
POINT 3
㧧
POINT 4
SIMULATION
NO. 46-10
ENGINE COLOR BALANCE MANUAL ADJUSTMENT [TXST]
xxx
245
755
OK
TEST
K
C
M
Y
0
EXECUTE
CLOSE
A:
A
㧦
xxx
B
㧦
xxx
C
㧦
xxx
D
㧦
xxx
㧧
POINT 1
㧧
POINT 2
㧧
POINT 3
㧧
POINT 4
SIMULATION
NO. 46-10
ENGINE COLOR BALANCE MANUAL ADJUSTMENT [TXST]
xxx
㨇
245
㨪
755
㨉
OK
TEST
K
C
M
Y
0
EXECUTE
CLOSE
TEXT
10-key
or end of print
[SYSTEM
SETTINGS]
key
EXECUTE
EXECUTE
A:
A
㧦
xxx
B
㧦
xxx
C
㧦
xxx
D
㧦
xxx
㧧
POINT1
㧧
POINT2
㧧
POINT3
㧧
POINT4
SIMULATION
NO.46-16
ENGINE
COLOR
BALANCE
MANUAL
ADJUSTMENT [ALL(B/W)]:PG
xxx
373
627
OK
TEST
0
EXECUTE
CLOSE
A:
A
㧦
xxx
B
㧦
xxx
C
㧦
xxx
D
㧦
xxx
㧧
POINT1
㧧
POINT2
㧧
POINT3
㧧
POINT4
SIMULATION
NO.46-16
ENGINE
COLOR
BALANCE
MANUAL
ADJUSTMENT [ALL(B/W)]:PG
xxx
373
627
OK
TEST
0
EXECUTE
CLOSE
10-key
or self print end
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...
Страница 425: ...Memo ...