MX-2300/2700 N/G SIMULATION 7 – 45
43
43-1
Purpose
: Setting
Function (Purpose)
: Used to set the fusing temperature in each
operation mode.
Section
: Fusing
Item
: Operation
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
* When [
↑
], [
↓
] button, [COLOR], or [BLACK] key is pressed,
the current set values is saved in EEPROM and RAM.
<Fusing temperature setting range and default values>
*1: Japan, China, AB_B
*2: U.S.A, Canada, Europe, U.K, Australia, Inch, AB_A
43-4
Purpose
: Setting
Function (Purpose)
: Used to set the fusing temperature in each
operation mode. (Continued from 43-01.)
Section
: Fusing
Item
: Operation
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK] button is pressed, the currently entered data are
saved to EEPROM and RAM.
When setting is completed, [OK] button returns to the normal
display.
* When [
↑
], [
↓
], [COLOR], or [BLACK] key is pressed, the current
set value is saved to EEPROM and RAM.
Item
Display
Content
Set
range
Default value
Group
A *1
Group
B *2
A
HL_UM READY
TH_UM set value in
READY standby
70 to
230
175
180
B
HL_LM READY
TH_LM set value in
READY standby
30 to
200
105
105
C
HL_US READY
TH_US set value in
READY standby
70 to
230
155
160
D
HL_UM PLAIN
PAPER BW
BW normal paper
TH_UM set value
70 to
230
170
175
E
HL_LM PLAIN
PAPER BW
BW normal paper
TH_LM set value
30 to
200
130
130
F
HL_US PLAIN
PAPER BW
BW normal paper
TH_US set value
70 to
230
180
180
G
HL_UM PLAIN
PAPER CL
COLOR normal
paper TH_UM set
value
70 to
230
170
175
H
HL_LM PLAIN
PAPER CL
COLOR normal
paper TH_LM set
value
30 to
200
130
130
I
HL_US PLAIN
PAPER CL
COLOR normal
paper TH_US set
value
70 to
230
180
180
J
WARMUP
FUMON
HL_UM T
Fusing paper front
rotation start
TH_UM set value
30 to
200
145
145
K
WARMUP
FUMOFF
HL_LM T
Fusing paper front
rotation start
TH_LM set value
30 to
200
75
75
L
WARM UP
END TIME
WARM UP
complete time
30 to
255
76
76
M
HL_UM HEAVY
PAPER
Heavy paper
TH_UM set value
70 to
230
170
170
N
HL_LM HEAVY
PAPER
Heavy paper
TH_LM set value
30 to
200
140
140
O
HL_US HEAVY
PAPER
Heavy paper
TH_US set value
70 to
230
175
175
P
HL_UM OHP
PAPER
OHP-TH_UM set
value
70 to
230
170
170
Q
HL_LM OHP
PAPER
OHP-TH_LM set
value
30 to
200
145
145
R
HL_US OHP
PAPER
OHP-TH_US set
value
70 to
230
170
170
S
HL_UM ENV
PAPER
Envelope TH_UM
set value
70 to
230
180
180
T
HL_LM ENV
PAPER
Envelope TH_LM
set value
30 to
200
145
145
U
HL_US ENV
PAPER
Envelope TH_US
set value
70 to
230
180
180
V
HL_UM E-
STAR
TH_UM set value
when preheating
30 to
200
145
142
W
TH_US E-
STAR
TH_US set value
when preheating
30 to
200
130
130
X
PRE-JOB
TH_UM set value
when resetting from
preheating
30 to
200
160
160
TH_UM
Fusing upper thermister main
TH_LM
Fusing lower thermister main
TH_US
Fusing upper thermister sub
HL_UM
Heater lamp upper main
HL_LM
Heater lamp lower main
HL_US
Heater lamp upper sub
Item
Display
Content
Set
range
Default value
Group
A *1
Group
B *2
0
A:
A
㧦
180
B
㧦
105
C
㧦
160
D
㧦
175
㧧
HL_UM READY
㧧
HL_LM READY
㧧
HL_US READY
㧧
HL_UM PLAIN
PAPER
BW
SIMULATION
NO.43
㧙
01
FUSER TEMP SETUP FOR PAPER
180
㨇
70
㨪
230
㨉
OK
TEST
CLOSE
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...
Страница 425: ...Memo ...