MX-2300/2700 N/G SIMULATION 7 – 54
[OTHER] button: Display of environment area, membrane
decrease correction steps and process control execution
counter, and model type.
* When [CLOSE] button is pressed, the display shifts to the copy
basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
<Display item and content description>
Mode
Page number
Display item (*: correction value)
Content description
Display range
Default
value
CPY/PRN
1/2
P (PROCON)
Left
BLACK : GB ***/*** DV ***/***
High density process control GB/DV
data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N (M)
(NORMAL
(MIDDLE))
Right
BLACK : GB ***/*** DV ***/***
High density normal (middle speed
display) GB/DV data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
2/2
N (L) (NORMAL
(LOW))
BLACK : GB ***/*** DV ***/***
High density normal (low speed
display) GB/DV data (KCMY)
GB: 230 to 850
DV: 0 to 700
GB: 600
DV: 400
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
OTHER
1/10
TN/TC
Left
TN HUD AREA
Toner control display humidity area
1 to 14
9
TN HUD DATA
Toner control display humidity AD
value
0 to 1023
0
TC TMP AREA
Transfer display temperature area
1 to 9
4
TC TMP DATA
Transfer display temperature AD value
0 to 1023
0
Right
TC HUD AREA
Transfer display humidity area
1 to 9
4
TC HUD DATA
Transfer display humidity AD value
0 to 1023
0
MD HUD AREA
Membrane decrease display humidity
area
1 to 14
9
MD HUD DATA
membrane decrease display humidity
AD value
0 to 1023
0
2/10
DRUM
Left
MD K STEP
Drum membrane decrease correction
step display (KCMY)
0 to 4
0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER
Membrane decrease drum traveling
distance area
0 to 20
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
3/10
VG
MD K REVISE(VG) : L *** M *** H***
Drum membrane decrease grid voltage
correction display (KCMY)
0 to 255
0
MD C REVISE(VG) : L *** M ***
MD M REVISE(VG) : L *** M ***
MD Y REVISE(VG) : L *** M ***
4/10
LD
MD K REVISE(LD) : L *** M *** H***
Drum membrane decrease laser power
voltage correction (KCMY)
0 to 255
0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
5/10
HV
MD K REVISE(HV) : L *** M *** H***
High density membrane decrease
environment GB correction display
(KCMY)
0 to 255
0
MD C REVISE(HV) : L *** M ***
MD M REVISE(HV) : L *** M ***
MD Y REVISE(HV) : L *** M ***
6/10
CP
MD K REVISE(CP) : L *** M *** H***
Drum membrane decrease
environment grid voltage correction
display (KCMY)
0 to 255
0
MD C REVISE(CP) : L *** M ***
MD M REVISE(CP) : L *** M ***
MD Y REVISE(CP) : L *** M ***
7/10
DL
MD K REVISE COL (DL): L *** M ***
Drum membrane decrease discharge
light quantity correction (%)
0 to 100
50
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
8/10
DL EV
MD K REVISE COL (DL EV): L *** M***
Drum membrane decrease
environment discharge light quantity
correction (%)
–100 to 100
0
MD C REVISE COL (DL EV): L *** M***
MD M REVISE COL (DL EV): L *** M***
MD Y REVISE COL (DL EV): L *** M***