MX-2300/2700 N/G TRANSFER SECTION L – 4
a. Intermediate transfer belt
* Do not replace the belt, blade, and primary transfer CL roller sep-
arately. When any of the three parts needs to be replaced,
replace the other two parts as well.
* When replacing the belt, be sure to apply stearic acid (UKOG-
0312FCZZ) and strontium titanate according to the instructions.
1)
Remove the primary trasnfer unit.
2)
Remove the cleaner unit.
3)
Remove the transfer guide plate left unit.
4)
Remove the parts.
5)
Fold the CL section of the transfer frame and remove the inter-
mediate transfer belt.
* When installing, set the lot number inside the belt to the front
side.
[Precautions for installation]
When replacing the belt, make sure not to scratch or fold it.
Do not touch the surface of the belt with bare hands.
(Applying the start powder)
1)
Install the primary transfer unit, laying it on the top surface.
* Make sure that the pressure on the CL roller has been
released.
2)
Apply the side seal powder (stearic acid) uniformly on the sur-
face of the belt (Figure 1).
* Apply the side seal powder uniformly on half of the surfaces
on both sides of the belt.
* Rub the belt with a cloth bag containing the side seal powder
so that the powder will be applied onto the belt.
3)
Turn the belt a 1/4 turn. (For the direction of the turn, see Fig-
ure 3.)
4)
Apply strontium titanate uniformly on the surface of the belt.
* Apply strontium titanate evenly on the surface of the belt.
* Apply 20 times (5 times transversally x 4 times longitudinally,
see Figure 2).
5)
Turn the belt twice (in the direction described in step 3).
* There may be some traces of strontium titanate left on the
surface of the belt.
6)
Turn the primary transfer unit over.
* Turn the unit over by lifting the cleaner unit side.
* Keep the primary transfer unit in a horizontal position (not to
lower the cleaner unit side) until it is installed on the
machine.
* Be sure not to allow strontium titanate to spread inside the
cleaner unit.
1
2
12345
AB-67
CL roller side
Apply strontium titanate all the way
beyond the boss.
Apply uniformly.
Cleaner unit
side
Turn the unit over by lifting the
cleaner unit side.
[Figure 1]
[Figure 2]
[Bottom surface]
[Number of times of application]
[Figure 3]
CL roller side
[Never lower the cleaner unit side.]
Cleaner
unit side
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...
Страница 425: ...Memo ...