MX-2300/2700 N/G TRANSFER SECTION L – 5
b. Primary transfer CL roller
1)
Remove the primary transfer unit.
2)
Remove the transfer guide plate left unit.
3)
Remove the screw, and remove the primary transfer CL roller
installation plate unit.
Remove the waste toner drive motor from the waste toner
drive unit.
* After assembling, check to confirm that it is not set at the
pressure release position.
c. Intermediate transfer blade
1)
Remove the primary transfer unit, and put it upside down.
2)
Remove the cleaner unit.
3)
Remove the transfer guide plate, and remove the intermediate
transfer blade.
* When installing, apply stearic acid onto the intermediate
transfer blade (A).
* Check the cleaner seal (B) and cleaner seal R (C). If any of
them is laid on the blade, replace it. (See step m for the
cleaner seal and step n for the cleaner seal R respectively.)
d. Primary transfer roller
e. Primary transfer conduction collar
f. Y auxiliary roller
1)
Remove the primary trasnfer unit.
2)
Remove the cleaner unit.
3)
Remove the intermediate transfer belt.
4)
Disengage the engagement on the front side, and remove the
primary transfer roller (A) and the primary transfer conduction
collar (B). Remove the Y auxiliary roller (C).
g. Belt drive gear
1)
Remove the primary trasnfer unit.
2)
Remove the cleaner unit.
3)
Remove the screws, and remove the belt drive gear.
A
B
C
1
A
A
A
A
C
B
B
B
B
2
3
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...