
MX-2300/2700 N/G SIMULATION 7 – 96
* Item A adjustment position
The main scanning direction paper size is greater than 216mm:
→
Reference: Main scanning direction print front image center
position (160mm from the BD sensor in the LSU unit)
±
120mm in
the main scanning direction
The main scanning direction paper size is 257mm or less:
Reference: Main scanning direction print front image center posi-
tion (160mm from the BD sensor in the LSU unit)
±
60mm in the
main scanning direction
* Adjustment direction
+ direction: Enlargement of magnification ratio
- direction: Reduction of magnification ratio
* When the adjustment value of item B to H is decreased by 1, the
main scanning print position is shifted to the front side by 0.1mm.
* When the adjustment value of item B to H is increased by 1, the
main scanning print position is shifted to the rear side by 0.1mm.
* Items J and K are displayed as "Display item: Detail of display."
Example: PAPER:CS1
50-12
Purpose
: Adjustment
Function (Purpose)
: Used to execute the scan image off-center
position adjustment. (Adjusted for each
scan mode.)
Section
:
Item
: Image quality (Image position)
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK], [
↑
], [
↓
] button, [COLOR], or [BLACK] key is
pressed, the currently entered data are saved to EEPROM and
RAM.
* When [CLOSE] button is pressed, the display is shifted to the
copy basic screen of simulation.
* Copying can be performed also by pressing [COLOR]/[BLACK]
key.
<Set range and default value of each setup>
Shift the pixel center position. The default value of the center is
3750 pixels.
A to C: When the adjustment value is increased, the center position
is shifted to the rear side. 1step=0.1mm
50-20
Purpose
: Adjustment
Function (Purpose)
: Used to execute the manual adjustment of
the main scanning direction registration
(color shift). (Backup value input)
Section
:
Item
: Image quality
Operation/Procedure
1)
Select the set item with [
↑
] and [
↓
] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [
↑
], an active display is made and
item is shifted.
If there is no item over [
↑
], the display grays out and the
operation is invalid.
If there is any item under [
↓
], an active display is made and
item is shifted.
If there is no item over [
↓
], the display grays out and the
operation is invalid.
2)
Enter the set value with 10-key.
* When [C] key is pressed, the entered value is cleared.
3)
When [EXECUTE] button is pressed, it is highlighted and the
currently entered data are saved to EEPROM and RAM. Then
the main scanning direction registration adjustment pattern is
printed.
After completion of printing, [EXECUTE] button returns to the
normal display.
4)
When [
↑
], [
↓
], [OK], [EXECUTE] button, [COLOR], or [BLACK]
key is pressed, the data are saved to EEPROM and RAM.
* When [C], [CA], [SYSTEM SETTINGS], or [EXECUTE] but-
ton is pressed during printing, the operation is interrupted.
* When the machine returns to the ready state after occur-
rence of an interruption, self printing is resumed.
Item
Display item
Set range
Set
value
Default
value
A
OC
OC document off-center
adjustment
1 to 99
50
B
SPF (SIDE1)
SPF front surface off-center
adjustment
1 to 99
50
C
SPF (SIDE2)
SPF back surface off-center
adjustment
1 to 99
50
0
A:
A
㧦
100
B
㧦
50
㧧
BK-MAG
㧧
MFT
SIMULATION
NO.50
㧙
10
PAPER CENTER OFFSET SETUP
100
㨇
60
㨪
140
㨉
OK
TEST
EXECUTE
CLOSE
C
㧦
50
㧧
CS1
D
㧦
50
㧧
CS2
0
A:
A
㧦
50
B
㧦
50
㧧
OC
㧧
SPF(SIDE1)
SIMULATION
NO.50
㧙
12
ORIGINAL CENTER OFFSET SETUP
50
㨇
1
㨪
99
㨉
OK
TEST
CLOSE
C
㧦
50
㧧
SPF(SIDE2)
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...
Страница 425: ...Memo ...