MX-2300/2700 N/G SELF DIAG AND TROUBLE CODE 8 – 15
F1-36
Finisher punch registration sensor
trouble (MX-FNX2)
F1-37
Finisher backup RAM trouble
F1-38
Finisher punch backup RAM trouble
(MX-FNX2)
F1-39
Finisher punch dust sensor trouble
(MX-FNX2)
F1-40
Saddle finisher punch power
interruption trouble (MX-FNX2)
F1-50
Finisher incompatibility trouble
F2-39
Process thermistor trouble
F2-40
Toner empty sensor abnormality
(BLACK)
F2-41
Toner empty sensor abnormality
(CYAN)
Trouble content
Sensor input value abnormality
Section
PCU
Case 1
Cause
Sensor breakage, harness disconnection, saddle
finisher control PWB trouble (MX-FNX2), punch
control PWB trouble (MX-FNX2)
Check
and
remedy
Use SIM3-2 to check the operation of the punch
timing sensor (FPTD).
Replace the finisher punch unit (Replace the punch
control PWB.).
Trouble content
Backup RAM data garbled
Section
PCU
Case 1
Cause
Finisher control PWB trouble, malfunction due to
electrical noises
Check
and
remedy
Replace the finisher control PWB.
Trouble content
Punch unit backup RAM data garbled
Section
PCU
Case 1
Cause
Punch control PWB trouble, malfunction due to
electrical noises
Check
and
remedy
Replace the punch control PWB.
Trouble content
Punch dust sensor detection trouble
Section
PCU
Case 1
Cause
Sensor breakage, harness disconnection, finisher
control PWB trouble (MX-FNX2), punch control PWB
trouble (MX-FNX2)
Check
and
remedy
Use SIM3-2 to check the operation of the sensor
punch dust sensor (FPDD).
Replace the finisher control PWB or the punch control
PWB.
Trouble content
When the punch unit power interruption is detected.
Section
PCU
Case 1
Cause
Harness disconnection, punch control PWB trouble
Check
and
remedy
Use SIM3-3 to check the operation punch motor
(FPNW).
Replace the finisher punch unit (Replace the punch
control PWB.).
Trouble content
Detection of finisher incompatible with MX-2700**/
2300**
Section
PCU
Case 1
Cause
Connection of the AR-F13, etc. which is incompatible
with MX-2700**/2300** is detected.
Check
and
remedy
Connect the MX-FNX1/MX-FNX2.
Trouble content
Process thermistor open
Section
PCU
Case 1
Cause
Process thermistor harness connection trouble
Check
and
remedy
Check the connection of the harness, connector of the
process thermistor.
Case 2
Cause
Process thermistor trouble
Check
and
remedy
Check the connection of the process thermistor.
Case 3
Cause
PCU PWB trouble
Check
and
remedy
Check the PCU PWB.
Trouble content
Toner empty sensor output abnormality. Sample level
25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check
and
remedy
Check the connection of the connector harness to the
PCU PWB. Check the connection of the toner empty
sensor.
Case 2
Cause
Connector harness trouble
Check
and
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check
and
remedy
Check the cartridge connection.
Trouble content
Toner empty sensor output abnormality. Sample level
25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check
and
remedy
Check the connection of the connector harness to the
PCU PWB. Check the connection of the toner empty
sensor.
Case 2
Cause
Connector harness trouble
Check
and
remedy
Check the harness disconnection.
Case 3
Cause
Cartridge trouble
Check
and
remedy
Check the cartridge connection.