MX-2300/2700 N/G SIMULATION 7 – 105
* When [BACK] button is pressed, the display returns to the result
display screen.
<List of adjustment items>
50-28
Purpose
: Adjustment
Function (Purpose)
: Used to display the adjustment result.
(Auto void adjustment (Service installation
adjustment) (5: result display)
Section
: —
Item
: Image quality
Operation/Procedure
1)
When [RESULT] button is pressed on the top menu screen,
the screen on the right is displayed.
2)
When [BACK] button is pressed, the display is shifted to the
top menu screen.
50-28
Purpose
: Adjustment
Function (Purpose)
: Used to display the data used for the
adjustment.
(Auto void adjustment (Service installation
adjustment) (6: data display))
Section
: —
Item
: Image quality
Operation/Procedure
1)
When the machine enters Simulation 50-28, the following
screen is displayed.
When [OC
⋅
SPF] button is pressed, the data used for the OC
adjustment and the SPF adjustment are displayed.
When [BK-MAG] button is pressed, the data used for BK main
scan magnification ratio adjustment are displayed.
When [PRINT] button is pressed, the data used for the print
position adjustment are displayed.
* If there is a page over [
↑
], an active display is shown and the
page moves up. If there is no page upward, the display
grays out and the operation is invalid.
If there is a page under [
↓
], an active display is shown and
the page moves down. If there is no page downward, the
display grays out and the operation is invalid.
* When [OK] button is pressed, the display is shifted to the top
menu screen.
<Data display item and description>
Menu display item
Content
LEAD
Print lead edge adjustment
OFFSET
Print off-center adjustment
ALL
Print lead edge, print of-center adjustment
SIMULATION
NO.50
̆
28
TEST
AUTO
IMAGE
POSITION
ADJUSTMENT
㧦
SERVICE
LEAD
OFFSET
ALL
1/1
0
CLOSE
0
SIMULATION
NO.50
̆
28
TEST
AUTO
IMAGE
POSITION
ADJUSTMENT : SERVICE
CLOSE
OC
㧦
LEAD
㧦㧖㧖㧔㧖㧖㧕
OFFSET
㧖㧖㧦㧔㧖㧖㧕
SUB
㧖㧖㧦㧔㧖㧖㧕
BK-MAG
㧦
BK:
㧖㧖㧖㧖
SPF
㧔
SIDE1
㧕
㧦
LEAD
㧖㧖㧔㧖㧖㧕
OFFSET
㧦㧖㧖㧔㧖㧖㧕
SUB
㧦㧖㧖㧔㧖㧖
㧕
SPF
㧔
SIDE2
㧕
㧦
LEAD
㧖㧖㧔㧖㧖㧕
OFFSET
㧦㧖㧖㧔㧖㧖㧕
SUB
㧦㧖㧖㧔㧖㧖
BACK
1/2
Adjustment item
(page)
Item display
Display content
Display range (difference from the
previous value)
Unit
OC
⋅
SPF
OC (1)
ADJ_OC
(SCAN/LEAD/OFST)
OC adjustment value, correction
value
1 to 99 (–99 to +99)
STEP
SCAN (F/C/R)/LEAD (F/C/R)
OC magnification ratio, lead
edge data
SCAN: –4.99 to +4.99
LEAD: –4.9 to +4.9
SCAN: %
LEAD: mm
DATA_OFFSET
R (U/M/L)/F (U/M/L)
OC off-center data
–4.9 to +4.9
mm
SCAN_MAIN
OC Main scan magnification ratio
correction value
–4.99 to +4.99
%
SPF1 (2)
ADJ_SPF1
(SCAN/LEAD/OFST)
SPF1 adjustment value,
correction value
1 to 99 (
±
99)
STEP
SCAN (F/C/R)/LEAD (F/C/R)
SPF1 magnification ratio, lead
edge data
SCAN: –4.99 to +4.99
LEAD: –4.9 to +4.9
SCAN: %
LEAD: mm
DATA_OFFSET
R (U/M/L)/F (U/M/L)
SPF1 off-center data
–4.9 to +4.9
mm
SCAN_MAIN
SPF1 main scan magnification
ratio correction value
–4.99 to +4.99
%
SPF2 (3)
ADJ_SPF2
(SCAN/LEAD/OFST)
SPF2 adjustment value,
correction value
1 to 99 (
±
99)
STEP
SCAN (F/C/R)/LEAD (F/C/R)
SPF2 magnification ratio, lead
edge data
SCAN: –4.99 to +4.99
LEAD: –4.9 to +4.9
SCAN: %
LEAD: mm
DATA_OFFSET
R (U/M/L)/F (U/M/L)
SPF2 off-center data
–4.9 to +4.9
mm
SCAN_MAIN
SPF2 main scan magnification
ratio correction value
–4.99 to +4.99
%
Status (4)
PAPER (OC/SPF1/SPF2)
Paper information
A4, A4R, A3, LT, LTR, WL
–
COUNT (OC/SPF1/SPF2)
Counter
0 to 255
Times
ERROR
Error history
–
Error code