MX-2300/2700 N/G ADJUSTMENTS 6 – 26
14-A Scan image magnification ratio adjustment
(Main scanning direction) (Document table
mode)
1)
Place a scale on the document table as shown in the figure
below.
2)
Enter the simulation 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key and shift from the simulation mode to the
copy mode and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100
±
1.0%).
If the copy magnification ratio is within the specified range (100
±
1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) – 5) until the copy magnification
ratio is within the specified range (100
±
1.0%).
14-B Scan image magnification ratio adjustment
(Sub scanning direction) (Document table
mode)
1)
Place a scale on the document table as shown in the figure
below.
2)
Enter the simulation 48-1 mode.
3)
Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key and shift from the simulation mode to the
copy mode and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100
±
1.0%).
If the copy magnification ratio is within the specified range (100
±
1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (SUB) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) – 5) until the copy magnification ratio is
within the specified range (100
±
1.0%).
15
Scan image magnification ratio
adjustment (RSPF mode) (Refer to
the MX-RPX1 SM.)
15-A Scan image magnification ratio adjustment
(Main scanning direction) (RSPF mode)
(Refer to the MX-RPX1 SM.)
15-B Scan image magnification ratio adjustment
(Sub scanning direction) (RSPF mode)
(Refer to the MX-RPX1 SM.)
10
20
30
40
50
60
70
80
90
100
1
10
120
1
30
140
150
CLOSE
0
A:
A
㧦
xx
B
㧦
xx
C
㧦
xx
D
㧦
xx
㧧
CCD(MAIN)
㧧
CCD(SUB)
㧧
SPF(MAIN)
㧧
SPF(SUB)
SIMULATION
NO.48-01
MAGNIFICATION
ADJUSTMENT
xx
1
99
OK
TEST
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
CLOSE
0
A:
A
㧦
xx
B
㧦
xx
C
㧦
xx
D
㧦
xx
㧧
CCD(MAIN)
㧧
CCD(SUB)
㧧
SPF(MAIN)
㧧
SPF(SUB)
SIMULATION
NO.48-01
MAGNIFICATION
ADJUSTMENT
xx
1
99
OK
TEST
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
Copy magnification ratio
(Original dimension – Copy dimension)
Original dimension
=
x 100 [%]
(Example 1)
Copy A
(Shorter than
the original)
Scale
(Original)
(Example 2)
Copy B
(Longer than
the original)
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...