MX-2300/2700 N/G SIMULATION 7 – 51
44
44-1
Purpose
: Setting
Function (Purpose)
: Used to set whether the correction func-
tions of the image forming (process) sec-
tion are enabled or not.
Section
: —
Item
: —
Operation/Procedure
1)
When the machine enters Simulation 44-01, the currently set
button is highlighted.
Set the item to be set to the normal display.
(Two or more items can be selected.) When an item is
selected, its button is highlighted. When the highlighted button
is pressed again, it returns to the normal display.
2)
When [EXECUTE] button is pressed, the current set value is
saved to EEPROM and RAM. After completion of setting,
[EXECUTE] button returns to the normal display.
<Set items>
*1: The transfer efficiency fluctuation is corrected with temperature
and humidity (absolute moisture). YES/NO setting. Transfer
high output voltage correction.
44-2
Purpose
: Adjustment
Function (Purpose)
: Used to perform the light quantity adjust-
ment of the process control sensor and the
registration sensor (two for resist are
adjusted simultaneously) and the surface
scan.
Section
: Process
Item
: Operation
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted and all
the drum motors are driven to start the adjustments of the pro-
cess control sensor and the registration sensor.
* After completion of the adjustments of the process control
sensor and the registration sensor, the drum motors are
stopped and the set contents are displayed. The necessary
data are saved to EEPROM.
[EXECUTE] button returns to the normal display.
* When [EXECUTE] button is pressed during adjustment of
the process control sensor and the registration sensor, the
monitor is terminated and the drum motor is stopped. [ECE-
CUTE] button returns to the original state.
Data saving is not performed, but the result at that time is
displayed.
* When an error occurs in the adjustment, "ERROR" is dis-
played in the value display section at the right of the error
item, and the drum motor is stopped. Data saving to
EEPROM is not performed at all and the operation is termi-
nated. [EXECUTE] button returns to the original state.
* When there is a page over [
↑
], the display becomes active
and shifts up to another page. When there is no page over
[
↑
], the display grays out and the operation is disabled.
* When there is a page under [
↓
], the display becomes active
and shifts down to another page. When there is nor page
under [
↓
], the display grays out and the operation is dis-
abled.
Display
Content
Set range
Default
value
HV
Normal operation high-
density process control YES/
NO setting
Normal
(Inhibit: 1: NO)
Highlighted
(Allow: 0: YES)
Allow
HT
Normal operation half-tone
process control YES/NO
setting
Allow
TC
Transfer output correction
YES/NO setting *1
Allow
MD VG
Membrane decrease grid
voltage correction YES/NO
setting
Allow
MD LD
Membrane decrease laser
power voltage correction
YES/NO setting
Inhibit
MD EV
Membrane decrease
environment grid voltage
correction YES/NO setting
Allow
MD DL
Membrane decrease
discharge light quantity
correction YES/NO setting
Allow
MD DL EV
Membrane decrease
environment discharge light
quantity correction YES/NO
setting
Inhibit
TN_HUM
Toner density humidity
correction YES/NO setting
Allow
TN_AREA
Toner density area correction
YES/NO setting
Allow
TN_LIFE
Toner density life correction
YES/NO setting
Allow
TN_COV
Toner density print rate
correction YES/NO setting
Allow
TN_PROCO
N
Toner density process control
correction YES/NO setting
Allow
TN_ENV
Toner density environment
correction YES/NO setting
Allow
TN_DRIP
Toner density correction,
unconditional supply YES/
NO setting
Allow
TN_SPEND
Toner compulsory
consumption mode YES/NO
setting
Allow
PHT
1Pixel half-tone process
control correction YES/NO
setting
Inhibit
AR_AUTO
Auto resist adjustment YES/
NO setting
Normal (Inhibit:
1: NO)
Highlighted
(Allow: 0: YES)
Allow
AR_ERROR
Error check YES/NO setting
during auto resist adjustment
Allow
DM_PHASE
Drum phase alignment YES/
NO setting
Allow
SENSITIVITY
Toner density correction
YES/NO setting
Inhibit
PRT_HT
Half tone process control
printer correction feedback
Enable/Disable setting
Allow
Display
Content
Set range
Default
value
CLOSE
0
SIMULATION NO.44-01
TEST
MODE SETTING
EXECUTE
1/2
HV
HT
TC
MD VG
MD LD
MD EV
MD DL
MD DL EV
TN_HUM
TN_AREA
TN_LIFE
TN_COV
TN_PROCON
TN_ENV
TN_DRIP
TN_SPEND
Содержание MX-2300 G
Страница 62: ...MX 2300 2700 N G ADJUSTMENTS 6 18 E F Yellow C D Magenta A B Cyan ...
Страница 374: ...MX 2300 2700 N G PHOTOCONDUCTOR SECTION i 7 3 6 7 9 8 10 2 5 7 9 1 4 11 ...
Страница 424: ...Memo ...
Страница 425: ...Memo ...