2.2.2.2 Low Word Register (LW)
LW is the Control Bank Low Word Register. This Read Only status register displays the
contents of the current conversion’s low word in the control bank. There is a one-to-one
correspondence between the contents of the control bank low word and the contents of
this register for the current conversion in progress.
Table 2-5. LW Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
BIASCON
REFM
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
ADDR
0xFF 0x04
Table 2-6. LW Fields
BIT
NAME
DESCRIPTION
31:14
///
Reserved
Reading returns 0. Write the reset value.
13:2
BIASCON
Bias Control
These bits turn the FETs on and off, as shown in
Figure 2-2. The bit number corresponds to the FET number in the figure.
IMPORTANT: bits 9-11 must always be written as 0b000. Writing a 1 to any
of these three bits can cause unpredictable results.
1 = FET ON
0 = FET OFF
1:0
REFM
Ref- Mux
Determines the signal connected to the negative reference of the
ADC during Idle Mode.
00 = VREF- (negative terminal of the internal bandgap reference).
01 = AN1 (UR/X-)
10 = AN3 (LR/Y-)
11 = AN9