LH79524/LH79525 User’s Guide
Real Time Clock
Version 1.0
12-3
12.2 Register Reference
12.2.1 Memory Map
The base address for the RTC is: 0xFFFE0000
12.2.2 Register Descriptions
12.2.2.1 Data Register (DR)
DR is the Read Data Register. The current value of the RTC counter can be read from
this register.
Table 12-1. RTC Register Summary
ADDRESS
OFFSET
NAME
DESCRIPTION
0x00
DR
Data Register
0x04
MR
Match Register
0x08
LR
Load Register
0x0C
CR
Control Register
0x10
IMSC
Interrupt Mask Set and Clear Register
0x14
RIS
Raw Interrupt Status Register
0x18
MIS
Masked Interrupt Status Register
0x1C
ICR
Interrupt Clear Register
0x20 - 0xFF
///
Reserved — Do not access.
Table 12-2. DR Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
RTCDR
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
RTCDR
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
ADDR
0xFF 0x00
Table 12-3. DR Fields
BIT
NAME
DESCRIPTION
31:0
RTCDR
RTC Data Register
Contains the current counter value, in hexadecimal.