11.2.2.25 Resistor Configuration Control 19 Register (RESCTL19)
The RESCTL19 Register allows software to configure a number of the LH79524/LH79525
pull-up/pull-down resistors. Bits marked ‘LH79524 Only’ read as 0 with all writes ‘reserved’
on the LH79525.
Table 11-50. RESCTL19 Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
PE7
PE6
PL7
PE5
PL6
PE4
PE3
PL5
RESET
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
ADDR
0xFF 0x94
Table 11-51. RESCTL19 Fields
BIT
NAME
DESCRIPTION
31:16
///
Reserved
Reading returns 0. Write the reset value.
15:14
PE7
Pin PE7/nWAIT/nDEOT Resistor Assignment
00 = No Pull-Down or Pull-Up
01 = Pull-Down
10 = Pull-Up
11 = Reserved
13:12
PE6
Pin PE6/LCDVEEN/LCDMOD Resistor Assignment
00 = No Pull-Down or Pull-Up
01 = Pull-Down
10 = Pull-Up
11 = Reserved
11:10
PL7
Pin PL7/D31 Resistor Assignment (LH79524 Only)
00 = No Pull-Down or Pull-Up
01 = Pull-Down
10 = Pull-Up
11 = Reserved
9:8
PE5
Pin PE5/LCDVDDEN Resistor Assignment
00 = No Pull-Down or Pull-Up
01 = Pull-Down
10 = Pull-Up
11 = Reserved
7:6
PL6
Pin PL6/D30 Resistor Assignment (LH79524 Only)
00 = No Pull-Down or Pull-Up
01 = Pull-Down
10 = Pull-Up
11 = Reserved