UARTs
LH79524/LH79525 User’s Guide
16-18
Version 1.0
8
TXE
Transmit Section
Enables the transmit section of the UART.
1 = Transmit section enabled. When the UART is disabled in the middle of
transmission, it completes the current character before stopping
0 = Transmit section not enabled
7
LBE
Loop Back Enable
Places the UART into Loopback Mode.
1 = Loopback is enabled
0 = Loopback is disabled
6:3
///
Reserved
Do not modify. When writing to this register, perform a
read-modified-write operation to this field.
2
SIRLP
IrDA SIR Low Power Mode
This bit selects the IrDA SIR encoding mode.
When this bit field is cleared to 0, low-level bits are transmitted as an active
HIGH pulse with a width of 3/16th of the bit period. When this bit field is set to
1, low-level bits are transmitted with a shorter pulse width. Enabling this bit
lowers power consumption, but may reduce the optical transmission distance.
1 = IrDA Low Power mode enabled
0 = IrDA Low Power mode disabled
1
SIREN
SIR Enable
This bit can be programmed to enable or disable the SIR
function. When the SIR ENDEC is enabled, data is transmitted and received
on the UARTIRRX and UARTIRTX pins. This data is converted to the SIR
format by the SIR ENDEC.
1 = SIR Enabled
0 = SIR Disabled
0
UARTEN
UART Enable
Enables the UART.
1 = Enables the UART. When the UART is disabled in the middle of
transmission or reception, it completes the current character before
stopping.
0 = UART disabled
Table 16-23. UARTCR Fields