LH79524/LH79525 User’s Guide
Reset, Clock, and Power Controller
Version 1.0
13-29
13.2.2.19 External Interrupt Configuration Register (INTCONFIG)
This register configures the individual external interrupts to be either edge-sensitive or
level-sensitive, and either active HIGH or active LOW. Following reset, all bits are 0 and
configure the external interrupts to be active LOW, level sensitive.
The corresponding edge-trigger interrupt should be cleared before enabling the edge-
trigger interrupt to avoid a false interrupt.
Table 13-46. INTCONFIG Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
INT7
INT6
INT5
INT4
INT3
INT2
INT1
INT0
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
ADDR
0xFF 0x80
Table 13-47. INTCONFIG Fields
BITS
NAME
DESCRIPTION
31:16
///
Reserved
Reading returns 0. Write the reset value.
15:14
INT7
Configures External Interrupt INT7
00 = Configures INT7 to be a LOW, level trigger.
01 = Configures INT7 to be a HIGH, level trigger.
10 = Configures INT7 to be a falling-edge trigger.
11 = Configures INT7 to be a rising-edge trigger.
13:12
INT6
Configures External Interrupt INT6
00 = Configures INT6 to be a LOW, level trigger.
01 = Configures INT6 to be a HIGH, level trigger.
10 = Configures INT6 to be a falling-edge trigger.
11 = Configures INT6 to be a rising-edge trigger.
11:10
INT5
Configures External Interrupt INT5
00 = Configures INT5 to be a LOW, level trigger.
01 = Configures INT5 to be a HIGH, level trigger.
10 = Configures INT5 to be a falling-edge trigger.
11 = Configures INT5 to be a rising-edge trigger.
9:8
INT4
Configures External Interrupt INT4
00 = Configures INT4 to be a LOW, level trigger.
01 = Configures INT4 to be a HIGH, level trigger.
10 = Configures INT4 to be a falling-edge trigger.
11 = Configures INT4 to be a rising-edge trigger.