![Sharp IV-S30 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/sharp/iv-s30/iv-s30_user-manual_367734045.webp)
2-5
Setting the Operating and System Conditions
2
[2] Image capture
In item "CAPTURE IMG" on the [TYPE RUN COND] menu, specify the range of lines which will be
captured during operation.
On the MAIN OPS MENU, move the cursor to "OPS-CND" item, and press the SET key.
PARTIAL-IMG
(partial image)
WHOLE-IMG
(whole image)
NO
(no image)
Description
2
CAPTURE IMG
- No image will be captured during operation. Measurements will
be carried out with an image being displayed.
- This mode only used to carry out measurements on an image
transmitted from a personal computer to the IV-S30.
1
MONITOR OUTPUT CAM1 CAM2 CAM1&2(HORIZ VERT)
2
CAPTURE IMG
PARTIAL-IMG
WHOLE-IMG
NO
3
MESSAGE DISPLAY YES(W/DATA) YES(W/O DATA) NO
[TYPE RUN COND]
1
2
Display when the "Standard/high
speed" camera type and
"CAM1&2" are selected.
- A whole image will be captured, irrespective of the window
settings for inspection or measurement.
- This mode is used to monitor portions of an image outside the
window set up for inspection or measurement.
Note: When the IV-S33M is used and "FULL+HALF" is selected for
the image capture mode (page 2-19 to 2-20), the controller
will process the whole area in full mode.
- An image of the specified lines, required for inspection or
measurement, will be captured.
- The processing time is shorter than in the "WHOLE-IMG" mode.
Note: When the IV-S33M is used and "EIA" is selected for the
camera, "PARTIAL-IMG" cannot be selected.
(The "PARTIAL-IMG" selection is not displayed.)
-
See page 2-1.
Ë
Ë
Ë
Ë
Ë
Operation procedure
1. On the [TYPE RUN COND] menu, move the cursor to item "CAPTURE IMG" with the up and
down keys, and press the SET key.
2. Move the cursor to "PARTIAL-IMG," "WHOLE-IMG" or "NO" with the left and right keys, and press
the SET key.
Ë
Ë
Ë
Ë
Ë
Example of a comparison of the capture times
Capture whole image
Capture partial image
480 lines
240 lines
-
- Image capture mode (full/half mode)
-
See page 2-20.
- When "Partial" is selected (when there are 240 scan lines)
* The image capture time may vary with the
position of the partial image. (In the
following case, maximum 0.4 ms)
When "Whole"
is selected
IV-S33M
IV-S31M/S32M
16.7 ms (high-speed camera and full mode)
8.3 ms (high-speed camera and half mode)
33.3 ms (standard camera)
33.3 ms (standard camera)
IV-S33M
IV-S31M/S32M
8.3 ms (high-speed camera and full mode)*
4.2 ms (high-speed camera and half mode)*
12.5 ms (high-speed camera and full + half mode)*
16.6 ms (standard camera)
16.6 ms (standard camera)