7-2
7
BGA/CSP Inspection
×
: No setting
Æ
Setting (display) of binary area conditions
When WINDOW has been set
to "NORMAL"
To the next page
To page 7-4
00 01 02 03 04 05
○
○ ○ × × × ×
1. Select (MEAS-COND).
When "MEASUREMENT 1" is selected.
1. Select a window type.
- BINARY-IMG-MASK
-
page 3-19
2. Enter a register number, and select
"YES."
- When the window type has been set
to "BINARY-IMG-MASK," only register
number 0 is available.
3. Select the circle under the register
whose binary area conditions you want
to set.
Select any of the register numbers of binary area conditions with a circle.
When item
2
REGISTER NO. is set to
"YES," a circle is displayed.
When CALC RESULT (see page 15-6) is
set to "YES," a circle is displayed.
When WINDOW has been set to "BINARY-IMG-MASK"
1
WINDOW NORMAL BINARY-IMG-MASK
2
REGISTER NO. 0
NO
YES
REGISTER NO.
3
BINARY AREA COND
NUMERIC CALC
COMPARE IMGS
-
Pages 3-23 to 3-25
-
Page 3-14
-
Page 3-10
Setting the measurement programs (pages 1-10 to 1-11: Select "INSPECT-BGA/CSP" on the "MEAS
SELECTION" line, and press the SET key)
[TYPE MEAS COND]
[MEASUREMENT1]
6
MEASUREMENT 1 INSPECT-BGA/CSP C1
(MEAS-COND)
OPS-MENU RETURN LOCK
[TYPE MEAS COND]
[MEAS COND]
6
MEASUREMENT 1
INSPECT-BGA/CSP C1
(MEAS-COND)
OPS-MENU RETURN LOCK EVALUATION NUM-CALC OUT-COND
1
MEAS SELECTION
NO POSI-DEVIATION CHK-DEG-MATCH
INSPECT-LEAD INSPECT-BGA/CSP
MEAS-BIN-AREA CNT-BIN-OBJ LABEL-BIN-OBJ
POINT-MEAS MULTI-POSI MULTI-MATCHES
2
SELECT CAMERA
CAM1 CAM 2 CAMPARE-IMGS(CAM1)
3
CHNG GRAY LEBEL
NO YES(00.0TIMES
γ
+
γ
- CHNG-L INCRS-M)
4
SPACE FILTER
NO
NUM-OF-TIMES 0(0~5)
1
WINDOW
NORMAL BINARY-IMG-MASK
2
REGISTER NO.
0(0~3) NO
YES
REGISTER NO.
3
BINARY AREA COND
NUMERIC CALC
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15