Numerical Calculations
15-14
15
0
1
2
3
4
5
6
7
N00
0
1
2
3
4
5
6
7
N00
N01
0
1
2
3
4
5
6
7
N00
N01
C000
3
2
2
3
4
5
7
8
[OUTPUT COND]
1
PAGE NO.
0(0~4) NO YES
2
SET POSITION
MOVE
3
INPUT SIGNAL
REGISTER NO.00(0~15)
MATCH M0(0~1) CRD-X0(0~1) CRD-Y0(0~1)
LVL G0 (0~1)
CALC N00(0~15) AUX.RLY-C000(0~127)
4
LOGIC SYMBOL
DEL
5
OUTPUT SIGNAL
AUX-RLY C000(0~127)
[PAGE0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
1
0
2
3
4
5
6
7
OUT
OPS-MENU RETURN LOCK
OUTPUT
[PAGE0]
INPUT0
LOGIC
OUTPUT
[PAGE0]
INPUT0
LOGIC
OUTPUT
[PAGE0]
INPUT0
LOGIC
To the next page
(4) Operations on the [OUTPUT COND] menu
1. On the [TYPE MEAS COND] menu, move the cursor to the "OUT-COND" item using the left and right keys,
and press the SET key.
-
The [OUTPUT COND] menu will be displayed.
2. Move the cursor to the "
1
PAGE NO." item using the up and down keys, and press the SET key. Select
"YES" using the left and right keys, and press the SET key.
-
Items
2
to
5
will be displayed.
3. Move the cursor to the "
2
SET POSITION" item using the up and down keys, and press the SET key.
- Move the cursor to the leftmost column of the INPUT 0 logic settings using the up/down and left/right keys,
and press the SET key.
4. Move the cursor to the "
3
INPUT SIGNAL" item using the up and down keys, and press the SET key.
- Move the cursor to "CALC N00(0 - 15)" using the left and right keys, and specify "CAL N00" using the up
and down keys. Then press the SET key.
5. Move the cursor to the "
4
LOGIC SYMBOL" item using the up and down keys, and press the SET key.
- Move the cursor to "-||-" using the left and right keys, and press the SET key.
-
The logical condition will be displayed in the leftmost column of the LOGIC row under INPUT 0.
- N00 refers to the N00 calculation result, that was entered on the [NUMERIC CALC] menu.
6. Move the cursor to the "
2
SET POSITION" item using the up and down keys, and press the SET key. Move
the cursor to the 1st column of the INPUT 0 logic settings using the left and right keys, and press the SET
key.
- As described in steps 4 and 5, enter "CALC N01" to be used as an input signal.
7. Move the cursor to the "
5
OUTPUT SIGNAL" item using the up and down keys, and press the SET key.
Press the SET key again.
- Specify "C000" for the auxiliary relay number using the left/right (change digits) and up/down keys, and
press the SET key.
-
The output coil for INPUT 0 will be displayed.
8. Move the cursor to the "RETURN" item using the up/down and left/right keys, and press the SET key.
-
The screen will return to the [TYPE MEAS COND] menu.
Column No.