17-3
Setting the Input/Output Conditions
17
1
MEAS INP I/F
PSERIAL CCD-TRIG
2
START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL USB
3
MANL TYPE CHNG
NO YES
4
PARALLEL INP X6
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
5
PARALLEL INP X7
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
6
STROBE OUT
NO Y0
1
MEAS INP I/F
PSERIAL CCD-TRIG
2
START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL USB
3
SERIAL OUTPUT
NO PC-LINK SERIAL
4
MANL TYPE CHNG
NO YES
5
PARALLEL INP X6
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
6
PARALLEL INP X7
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
7
STROBE OUT
NO Y0
[SYSTEM COND]
1
I/O CONDITIONS
(TO NEXT SUB-MENU)
2
COMM.SET
(TO NEXT SUB-MENU)
[I/O CONDITIONS]
1
MEAS INP I/F
PSERIAL CCD-TRIG
2
START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL USB
3
OUTPUT OBJ TYPE PARALLEL USB
4
MANL TYPE CHNG
NO YES
5
PARALLEL INP X6
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
6
PARALLEL INP X7
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
7
STROBE OUT
NO Y0
OPS-MENU RETURN LOCK
After selecting
"REG-REF," change
0 to 4 using the
up/down keys.
Change
Y0 to Y7 using
the up/down keys.
● Select "
1
MEAS INP I/F = CCD-TRIG" and "START CCD SAMPL = USB"
and press the SET key.
The details of the individual items on the [I/O CONDITIONS] menu are the
same as described on pages 17-1 to 17-2.
The "64OBJ-CHG" is only displayed here when the IV-S33M is used. When the IV-
S31M/S32M is used, "EXT-INP" will be displayed here.
● Select "
1
MEAS INP I/F
=
CCD-TRIG" and "
2
START CCD SAMPLE
=
PARALLEL"
and press the SET key.
● Select "
1
MEAS INP I/F
=
CCD-TRIG" and "
2
START CCD SAMPLE
=
AUTO(EDGE LEVL)"
and press the SET key.
On the MAIN OPS MENU, move the cursor to "SYS-CND," and press the SET key.
-
On the [SYSTEM COND] menu, move the cursor to item "
1
I/O CONDITIONS"
and press the SET key.
-
On the [I/O CONDITIONS] menu, move the cursor to "
1
MEAS INP I/F" and
press the SET key. Then select "CCD-TRIG" and press the SET key.
[2] When you want to select the "CCD-TRIG" on the "MEAS INP I/F" line.
Input/output condition
Setting details
7
’READY’ ON
Set the time to turn ON the READY output signal.
(When the measurement start input source is set to parallel, the object type
change signal will also be parallel, and results will be output as parallel signals.
-
See page 17-5.)
Æ
At the end of an image capture
When the controller stops capturing the image, the READY signal turns ON.
Æ
At the end of a measurement
When the controller stops measuring, the READY signal turns ON.