Operating Instructions – MOVITRAC® LTP
35
8
Parameter access and reset
Parameters
8.1.2
Parameter access mode
To enter the
parameter access mode
, press the <Navigate> button for more than
1 second. The display changes from indicating operational speed to "PX-XX", where
X-XX represents the parameter last accessed during the previous commissioning ses-
sion. The value of X-XX can be incremented or decremented using the <up> / <down>
keys. The parameter scrolling mechanism rolls over from the max. to min. parameter
number and vice versa.
Pressing and releasing the <Navigate> key once more will then display the current value
of the selected parameter. This can then be edited within the limits of that parameter,
unless
parameter write access
has been disabled (P2-38).
Pressing the <Navigate> key once more toggles back to display the parameter number
in case further editing is required.
If the <Navigate> key is held for approx. 1 second, the display reverts to displaying the
real-time values (speed / frequency or current / load). The display will also revert to
displaying the selected real-time value if no buttons are pressed for > 30 seconds in
P1-01 … P4-10. This does not apply to parameters P0-01 ... P0-30, in which the drive
remains in parameter access mode.
The parameters are split into standard parameters (e.g. max / min speed), which can be
accessed in the basic menu and advanced parameters, which can be accessed in the
extended menu.