34
Operating Instructions – MOVITRAC® LTP
8
Parameter access and reset
Parameters
8
Parameters
8.1
Parameter access and reset
Accessing and changing parameters is done in an intuitive manner, as illustrated below:
8.1.1
Real time display
Normal (real-time) display mode allows the key variables listed below to be displayed in
real time.
The user can scroll between these variables by pressing and releasing the <Navigate>
key within 1 second. The scrolling mechanism rolls over from motor current back to
speed.
55992AEN
REAL-TIME DISPLAY
EDIT PARAMETER
VALUE
EDIT PARAMETER
NUMBER
Press <Navigate> key
Press <Navigate>
key for > 1 second
Press <Navigate> key for > 1 second
or no key activity for > 30 seconds
Information type
Letter displayed
Value displayed
Unit of measurement
Estimated speed
–
0 ...
±
60000
rpm
Output frequency
H
0 ...
±
2000
Hz
Output current
A
0 ... 100.0
Amp
Output power
P
0 ... 300
kW
P6..
P60.
P600