Operating Instructions – MOVITRAC® LTP
27
6
Operating the keypad
Startup
6
Startup
6.1
Operating the keypad
Each MOVITRAC
®
LTP has an integrated keypad as standard, allowing drive operation
and set up without any additional equipment.
The keypad consists of 5 keys with the following functions:
The Start / Stop buttons on the keypad are disabled when the parameters have their
factory default settings. To enable the operation of the <start> / <stop> buttons on the
keypad, set P1-12 to 1 or 2 (see chapter 8.2.1, "Standard parameters").
The Navigate key alone is used to gain access to the parameter edit menu. Pressing
and holding this key (> 1 second) allows the user to toggle between the parameter edit
menu and the real time display (where the drive operating status / running speed is
displayed). By pressing this key (< 1 second) the user is able to toggle between the
operating speed and operating current during drive operation.
Start / Run
Enable running of motor
Stop / Reset
Stop motor / Reset trip
Navigate
Press and release to display A / Hz / rpm
Press and hold to enter / exit parameter edit mode
Up
Increase Parameter / Value
Down
Decrease Parameter / Value
54787AXX
[1]
Display
[2]
Start
[3]
Stop / Reset
[4]
Navigate
[5]
Up
[6]
Down
[1]
[2]
[3]
[4]
[5]
[6]
NOTE
To reset to factory default settings, press the Up, Down, and Stop buttons simulta-
neously for > 2 s. The display then shows "P-deF". Press the Stop button to acknowl-
edge the change and to reset the drive.