4
Mechanical installation
Central opening/closing mechanism
Operating Instructions – MOVIFIT
®
FC
38
3. Check the EBOX for correct position.
NOTICE
The central opening/closing mechanism may be damaged as a result.
Destruction of central opening/closing mechanism.
• Carefully close the EBOX manually if it is in a tilted mounting position.
• Make sure that the EBOX does not get jammed.
4. Tighten the retaining screw up to the stop using a tightening torque of 7 Nm.
EBOX
ABOX
813384075
NOTICE
If the torque is too high, the central opening/closing mechanism can be
destroyed.
• Tighten the retaining screw with a maximum tightening torque of 7 Nm.
• If there is a noticeable counter-torque, remove the EBOX again and check to
see that the gasket is seated properly. If necessary, press the gasket firmly into
the groove.
• Never tighten the retaining screws with impermissibly high tightening torques.
5. MOVIFIT
®
is closed correctly when the redirector of the closing mechanism [2] is
on the mounting panel [1].
0
Z
Z
[1]
[1]
[2]
[2]
813392395
21316996/EN – 12/2014