7
Operation
Status LEDs MOVIFIT® FC
Operating Instructions – MOVIFIT
®
FC
150
"RUN" LED
The following table shows the statuses of the "RUN" LED:
LED
Meaning
Measure
Off
MOVIFIT
®
not ready for opera-
tion.
No 24 V power supply.
• Check DC 24 V supply.
• Switch on MOVIFIT
®
again. Re-
place EBOX if problem occurs
several times.
Green
Illuminated
MOVIFIT
®
component hardware
OK.
-
Green
Illuminated
If "BUS-F" LED is off:
MOVIFIT
®
operating correctly.
MOVIFIT
®
is currently exchanging
data with the DP master and all
subordinate drive systems.
-
Green
Flashing
PROFIBUS address is set equal
to 0 or higher than 125.
Check the PROFIBUS address that
is set in the MOVIFIT
®
ABOX.
Yellow
Illuminated
MOVIFIT
®
is in initialization
phase.
-
Red
Illuminated
Internal unit error
Switch on MOVIFIT
®
again. Replace
EBOX if problem occurs several
times.
21316996/EN – 12/2014