9
Technical data
Dimension drawings
Operating Instructions – MOVIFIT
®
FC
202
9.15.8
ABOX with round connector (Intercontec), motor output pointing forward:
The following figure shows the minimum installation clearance of the hybrid ABOX
with circular connector (Intercontec) and motor output pointing forward:
[1
] R
75
[2] 191
75
127
9007204023573387
[1] Smallest permitted bending radius of bulk cable: 75 mm
[2] Minimum distance to the front of the ABOX: 191 mm
21316996/EN – 12/2014