6
Startup
Description of the DIP switches
Operating Instructions – MOVIFIT
®
FC
134
MTF..-15
DRS – DRE
V = AC 3 x 400 V, 50 Hz or AC 3 x 460 V, 60 Hz
MOVIFIT
®
Assigned motor and brake
1)
S10/5 = OFF
S10/5 = ON
W
connection
m
connection
W
connection
m
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
MTF..003..-15 DRS71S4
BE05
BE1 DR63L4
2)
BR03 BR03 DR63L4
2)
BR03 BR03 -
-
-
MTF..005..-15 DRS71M4
BE1
BE05 DRS71S4
BE05
BE1 DRS71S4
BE05
BE1 DR63L4
2)
BR03 BR03
MTF..007..-15 DRE80M4
BE1
BE05 DRS71M4
BE1
BE05 DRS71M4
BE1
BE05 DRS71S4
BE05
BE1
MTF..011..-15 DRE90M4
BE2
BE1 DRE80M4
BE1
BE05 DRE80M4
BE1
BE05 DRS71M4
BE1
BE05
MTF..015..-15 DRE90L4
BE2
BE1 DRE90M4
BE2
BE1 DRE90M4
BE2
BE1 DRE80M4
BE1
BE05
MTF..022..-15 DRE100L4
BE5
BE2 DRE90L4
BE2
BE1 DRE90L4
BE2
BE1 DRE90M4
BE2
BE1
MTF..030..-15 DRE100LC4
BE5
BE2 DRE100 L4
BE5
BE2 DRE100 L4
BE5
BE2 DRE90 L4
BE2
BE1
MTF..040..-15 DRE132S4
BE5
BE11 DRE100LC4
BE5
BE2 DRE100LC4
BE5
BE2 DRE100L4
BE5
BE2
1) Possible brake voltages: 120 V, 230 V, 400 V
2) This motor is included in the data set.The motor is only available as IEC motor with V = 3 x 400 V, 50 Hz (no motor with 50/60 Hz
voltage range).
MTF..-16
DRP
V = AC 3 x 400 V, 50 Hz
MOVIFIT
®
Assigned motor and brake
1)
S10/5 = OFF
S10/5 = ON
W
connection
m
connection
W
connection
m
connection
Motor
Brake
Motor
Brake
Motor
Brake
Motor
Brake
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
Stand-
ard
Op-
tion
MTF..003..-16 -
-
-
-
-
-
-
-
-
-
-
-
MTF..005..-16 -
-
-
-
-
-
-
-
-
-
-
-
MTF..007..-16 DRP90M4
BE1
BE2 -
-
-
-
-
-
-
-
-
MTF..011..-16 DRP90L4
BE2
BE1 DRP90M4
BE1
BE2 DRP90M4
BE1
BE2 -
-
-
MTF..015..-16 DRP100M4
BE2
BE5 DRP90L4
BE2
BE1 DRP90L4
BE2
BE1 DRP90M4
BE1
BE2
MTF..022..-16 DRP100L4
BE5
BE2 DRP100M4
BE2
BE5 DRP100M4
BE2
BE5 DRP90L4
BE2
BE1
MTF..030..-16 DRP112M4
BE5
BE11 DRP100L4
BE5
BE2 DRP100L4
BE5
BE2 DRP100M4
BE2
BE5
MTF..040..-16 DRP132M4
BE5
BE11 DRP112M4
BE5
BE11 DRP112M4
BE5
BE11 DRP100L4
BE5
BE2
1) Possible brake voltages: 120 V, 230 V, 400 V
21316996/EN – 12/2014
Содержание MOVIFIT FC
Страница 2: ...SEW EURODRIVE Driving the world ...
Страница 225: ......
Страница 226: ......
Страница 227: ......