7
Operation
Status LEDs MOVIFIT® FC
Operating Instructions – MOVIFIT
®
FC
164
"FDI.." LEDs
The following table shows the statuses of the "FDI.." LEDs:
LED
Meaning
Off
LOW level at input F-DI.. or open
Parameterization is active.
Yellow
Illuminated
HIGH level at input F-DI..
Display test, 2 s after reset
Red
Illuminated
Error at input F-DI.. (except discrepancy errors)
"FDO.." LEDs
The following table shows the statuses of the "FDO.." LEDs:
LED
Meaning
Off
F-DO.. output is inactive (switched off).
Yellow
Illuminated
F-DO.. output is active.
Display test, 2 s after reset
Red
Illuminated
Error at output F-DO..
INFORMATION
The "FDO.." LEDs are only relevant for the S12A safety option.
"F-FUNC" LED
The following table shows the statuses of the "F-FUNC" LED:
LED
Meaning
Off
Safety function is not active or error at output F-DO_STO.
Yellow
Illuminated
Drive is in safe torque off mode, F-DO_STO without voltage.
Yellow
Flashing
250 ms cy-
cle
Brake ramp is active (SLS, SS1a).
Yellow
Flashing
1 s cycle
Speed monitoring is active (SLS).