170
Code
Error
Possible cause
Measure
07
DC link voltage
too high
Ramp time too short.
Extend the ramp time.
Reset error
1)
.
Faulty connection between
brake coil/braking resistor
Check the braking resistor/brake coil connection.
Correct, if necessary.
Reset error
1)
.
Incorrect internal resistance
of brake coil/braking resistor
Check internal resistance of brake coil/braking re-
sistor (see chapter "Technical data").
Reset error
1)
.
Thermal overload in braking
resistor; wrong size of brak-
ing resistor selected.
Dimension the braking resistor correctly.
Reset error
1)
.
Invalid voltage range of sup-
ply input voltage
Check supply input voltage for permitted voltage
range.
Reset error
1)
.
08
Speed monitor-
ing
Speed deviation due to op-
eration at the current limit
Reduce the load on the drive.
Increase the n-monitoring delay time.
Reset error
1)
.
09
Startup
Incorrect startup/parameteri-
zation (e.g. with
MOVITOOLS
®
MotionStudio).
Repeat startup with correct settings.
If this does not work (e.g. in Expert mode):
• Set parameter
P802 Factory setting
to "Deliv-
ery state" once.
• Switch to Easy mode once (DIP switch S10/2
= OFF).
Reset error
1)
.
11
Thermal over-
load of the out-
put stage or in-
ternal unit error
Ambient temperature too
high.
Lower ambient temperature.
Reset error
1)
.
Heat build-up at MOVIFIT
®
Prevent heat build-up.
Reset error
1)
.
Drive load too high.
Reduce the load on the drive.
Reset error
1)
.
15
24 V supply
Supply voltages 24V_C
and/or 24V_P are too low.
Check 24 V supply voltages 24V_C and/or
24V_P.
Reset error
1)
.
17 - 24
37
CPU error
CPU error
Reset error
1)
.
25
EEPROM error
Fault when accessing
EEPROM
Set parameter
P802
to "Delivery state".
Reset error
1)
.
Re-parameterize the unit.