9
Technical data
Interfaces
Operating Instructions – MOVIFIT
®
FC
183
9.8.3
Fieldbus interfaces
One of the following protocols can be used for communication depending on the
EBOX and ABOX designs:
PROFIBUS interface
PROFIBUS
Function level
Classic
Technology
PROFIBUS protocol variant
PROFIBUS DP/DPV1
Supported baud rates
9.6 kBd – 1.5 MBd / 3 – 12 MBd (with automatic detection)
Bus termination
Can be activated via DIP switch S1
Maximum line length
9.6 kBd: 1200 m
19.2 kBd: 1200 m
93.75 kBd: 1200 m
187.5 kBd: 1000 m
500 kBd: 400 m
1.5 MBd: 200 m
12 MBd: 100 m
To extend the length, several segments can be coupled using repeaters.
The max. expansion/cascading depth can be found in the manuals for
the DP Master or the repeater modules.
Address setting
Addresses 1 to 125 can be set using DIP switches in the connection box
DP ident number
Classic
600 A
hex
(24586
dec
)
Technology
600B
hex
(24587
dec
)
GSD file name
Classic
SEW_600A.GSD
Technology
SEW_600B.GSD
Bitmap file name
Classic
SEW600AN.BMP SEW600AS.BMP
Technology
SEW600BN.BMP SEW600BS.BMP
21316996/EN – 12/2014