7
Operation
Status LEDs MOVIFIT® FC
Operating Instructions – MOVIFIT
®
FC
162
"STO" LED
The following table shows the statuses of the "STO" LED:
LED
Meaning
Yellow
Illuminated
Drive is in Safe Torque Off ("STO active").
Off
Drive is not in Safe Torque Off ("STO inactive").
"F-STATE" LED
The following table shows the statuses of the "F-STATE" LED:
LED
Meaning
Measure
Green
Illuminated
The S11 option is currently per-
forming a cyclical data ex-
change with the F-Host (data
exchange).
Standard operating state.
-
Red
Illuminated
Fault status in the safety part.
24V_O supply voltage not avail-
able.
• Read diagnostics in F-Host.
• Eliminate the cause of the fault
and acknowledge in the F-Host.
Off
S11 option is currently in the ini-
tialization phase.
S11 option is not available or is
not configured in the bus master
(slot 1 is empty).
• Check voltage supply.
• Check configuration of the bus
master.
Red/green
Flashing
A fault occurred in the safety
part; cause of the fault already
remedied – acknowledgement
required.
• Acknowledge fault in the F-Host
(reintegration).
21316996/EN – 12/2014