9
Technical data
Cable type "A" hybrid cable
Operating Instructions – MOVIFIT
®
FC
187
9.9
Cable type "A" hybrid cable
9.9.1
Mechanical design
[1]
[2]
A
GNYE
BK U1
RD13
WH14
BK V1
BK W1
BU 15
BK1
BK2
839041931
[1] Overall shield
[2] Shield
Cable type
A
8179530
• Supply cores:
7 x 1,5 mm
2
• Control core pair:
2 x 0,75 mm
2
• Conductor insulation:
TPE-E (Polyester)
• Conductor:
Bare E-Cu litz wire, extra fine wires with individual wire
0.1 mm
• Shield:
E-Cu wire, tinned
• Overall diameter:
Max. 15.9 mm
• Color of outer cable
jacket:
Black
• Outer cable jacket insu-
lation:
TPE-U (Polyurethan)
9.9.2
Electrical properties
• Conductor resistance for 1.5 mm
2
(at
20 °C):
max. 13 Ω/km
• Conductor resistance for 0.75 mm
2
(at
20 °C):
max. 26 Ω/km
• Operating voltage for 1.5 mm
2
conduc-
tor:
Max. 600 V according to
• Operating voltage for 0.75 mm
2
conduc-
tor:
Max. 600 V according to
• Insulation resistance at 20 °C:
min. 20 MΩ x km
21316996/EN – 12/2014
Содержание MOVIFIT FC