5
Electrical installation
Electrical connections
Operating Instructions – MOVIFIT
®
FC
111
5.13.10 X30, X31: PROFINET POF interface
The following table shows information about this connection:
Function
PROFINET interface SCRJ / POF (at POF option L10)
Connection type
Push-pull SCRJ
Wiring diagram
1
2
Assignment
No.
Name
Function
1
TX
Transmit line (POF)
2
RX
Receive line (POF)
5.13.11 X13: DC 24 V supply
The following table shows information about this connection:
Function
DC 24 V supply of POF option L10 (at the ABOX, plugged at the factory)
Connection type
M12, 5-pole, female, A
‑
coded
Wiring diagram
1
4
3
2
5
9007201519557259
Assignment
No.
Name
Function
1
+24V_C
24 V supply
2
res.
Reserved
3
0V24_C
Reference potential
4
res.
Reserved
5
res.
Reserved