3 Command Line Reference
spth
gpth
setPowerThresholds
getPowerThresholds
ExtPowerSupply
0.0 . . . 30.0 V
RxControl: File > Power Mode > Monitoring
This command sets the supply voltage level at which the receiver enters power-saving mode.
It is to be used in conjunction with the
command.
When the supply voltage (e.g. from an external battery) drops below the threshold set with
the
ExtPowerSupply
argument, the receiver enters low-power sleep mode for a duration given
by the
command. At the end of this duration, the receiver wakes
up and either resumes operation normally if the supply voltage is sufficient, or otherwise
returns into sleep mode.
Each time the receiver wakes up, it applies the boot configuration. For the receiver to
wake up in the current configuration, it has to be saved in the boot configuration with the
command. When the condition to go to sleep is met at the time the
command is entered, the user has 30 seconds to save the configu-
ration before the receiver goes to sleep.
When the
ExtPowerSupply
argument of this command is zero, or when the
StandbyPeriod
ar-
gument of
is zero, the voltage threshold is not monitored.
Note that only the voltage of the main PWR connector is monitored. If the receiver is powered
over Ethernet (PoE), the voltage monitoring is not applicable.
Example
If you want the receiver to go to sleep for an hour each time the external power supply drops
below 11.4V, use:
COM1>
ssm, 3600 <CR>
$R: ssm, 3600
StandbyMonitoring, 3600
COM1>
spth, 11.4 <CR>
$R: spth, 11.4
PowerThresholds, 11.4
COM1>
eccf, Current, Boot <CR>
$R: eccf, Current, Boot
CopyConfigFile, Current, Boot
COM1>
98
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...