3 Command Line Reference
Examples:
COM1, COM1+COM2, all
(which is actually an alias for
COM1+COM2
).
•
Distance
is a number between
-20
and
20
with a default value of
0
, and up to 2 decimal
digits. An error is returned if more digits are provided. The "m" indicates that the value
is expressed in meters. Note that this "m" should not be typed when entering the
command.
Examples:
20, 10.3, -2.34
•
Time
is a number between
1
and
50
, with no decimal digit (i.e. this is an integer value).
This value is expressed in seconds.
Examples:
1, 10
•
Message
is a string with a maximum length of 120 characters. The default value of
that argument is "
Unknown
". When spaces must to be used, the string has to be put
between quotes and these enclosing quotes are not considered part of the string. The
list of allowed characters in strings is:
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789
!#%@()*+-./:;<=>?[\]^_‘{|}~
Example: "
Hello World!
"
•
Password
is a password argument with a maximum length of 20 characters (40/2). Pass-
word arguments are always named
Password
or
Key
. Only half of the total password
length is available to the user, the other half being reserved by the system. Passwords
are obfuscated by the receiver so that they cannot be read back in command replies.
In addition to the characters above (see the
Message
argument), special characters are
allowed in passwords using the corresponding escape sequence:
–
Type
%%DQ
to obtain
"
–
Type
%%SQ
to obtain
’
–
Type
%%DL
to obtain
$
–
Type
%%AM
to obtain
&
–
Type
%%CM
to obtain
,
Example: "
ab%%AM123
"
•
Mode
is a range of individual values that cannot be combined (they are not preceded
by a "
+
" sign). Either
off
or
on
can be selected for that argument and the default value
is
on
.
Example:
on
77
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...