4 SBF Reference
EndOfMeas
Number:
5922
"OnChange"
interval: internal measurement rate (receiver-type depen-
dent)
This block marks the end of the transmission of all measurement-related blocks belonging
to a given epoch.
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
Receiver time stamp, see 4.1.3
u2
1
week
65535
Padding
u1[..]
Padding bytes, see 4.1.5
314