4 SBF Reference
NTRIPClientStatus
Number:
4053
"OnChange"
interval: 1s
This block reports the current status of the NTRIP client connections.
Parameter
Type Units
Do-Not-Use
Description
Sync1
c1
Block Header, see 4.1.1
Sync2
c1
u2
ID
u2
Length
u2
1
byte
u4
0.001
s
4294967295
Receiver time stamp, see 4.1.3
u2
1
week
65535
N
u1
Number of NTRIP client connections for which status is provided in this
block, i.e. number of
NTRIPClientConnection
sub-blocks.
SBLength
u1
1
byte
Length of one
NTRIPClientConnection
sub-block
NTRIPClientConnection
...
...
A succession of N
NTRIPClientConnection
sub-blocks, see definition
below
Padding
u1[..]
Padding bytes, see 4.1.5
NTRIPClientConnection
sub-block definition:
Parameter
Type Units
Description
CDIndex
u1
Index of the NTRIP connection (1 for NTR1, 2 for NTR2, etc) for which status is provided
in this sub-block.
Status
u1
NTRIP client status:
0:
Connection disabled
1:
Initializing
2:
Running, differential corrections are being received and the link statistics is
available in the
block.
3:
Error detected, the error code is provided in the next field.
4:
Retrying, client encountered an error, we are trying to reconnect. The error
code is provided in the next field.
5:
Disabled since the settings are a duplicate of another active NTRIP connection.
ErrorCode
u1
NTRIP error code:
0:
No error
1:
Initialization error (e.g. source table retrieval failure)
2:
Authentication error
3:
Connection error
4:
Mountpoint does not exist
5:
Mountpoint unavailable
6:
Waiting for GGA
7:
GGA sending disabled when required by mountpoint
8:
Resolving host failed
9:
Out of region
10:
TLS setup error
11:
TLS handshake error
12:
TLS fingerprint error
13:
TLS time not known
254: Unknown error
Info
u1
Bit field indicating miscellaneous info about the Connection status:
Bit 0:
TLS was used to make secure NTRIP connection if this bit is set
Bits 1-7: Reserved
Padding
u1[..]
Padding bytes, see 4.1.5
459
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...