4 SBF Reference
OutputStatsSub
sub-block definition:
Parameter
Type Units
Description
CD
u1
Identifier of the connection to which this information applies:
Value of Connection type
Example
CD
0-31
COMx, with
x
=CD
1: COM1
32-47
USBx, with
x
=CD-32
33: USB1
48-63
OTGx, with
x
=CD-48
49: OTG1
64-95
IPx, with
x
=CD-54
64:IP10
96-127 DSKx, with
x
=CD-96
97:DSK1
128-159 NTRx, with
x
=CD-128 (NTRIP connections)
129:NTR1
160-191 IPSx, with
x
=CD-160 (IP server connections)
161:IPS1
192
BT01 (Bluetooth connection)
193
BT02 (Bluetooth connection)
196
UHF1 (UHF Modem)
200-205 IPRx, with
x
=CD-200 (IP receive connections)
201:IPR1
210
DCL1 (cellular data-call connection)
214
CAN1 (CAN stream interface)
215-219 Reserved
220
SPI1 (SPI interface)
221-255 Reserved
N2
u1
Number of
OutputTypeSub
sub-blocks included at the end of this
OutputStatsSub
sub-block
AllowedRate
u2
1
kbyte / s Maximum datarate recommended on this connection
NrBytesProduced
u4
1
byte
Total number of bytes produced by the receiver. See also the
NrBytesSent
field.
NrBytesSent
u4
1
byte
Total number of bytes actually sent (i.e. without congestions or transmission
errors).
The ratio of
NrBytesSent
to
NrBytesProduced
gives an indication of the
amount of bandwidth overload.
NrBytesSent
and
NrBytesProduced
are 32-bit counters. If one of them
overflows, both counters are reset to zero.
NrClients
u1
Number of clients currently connected to this connection. Most connection types
can only serve one client at a time, but each IP server (IPS) port can serve up to
eight simultaneous clients.
Note that when
NrClients
is more than one, the fields
NrBytesProduced
and
NrBytesSent
are the number of bytes produced and sent to each individual
client.
Reserved
u1[3]
Reserved for future use
Rev 1
Padding
u1[..]
Padding bytes, see 4.1.5
OutputType
...
...
A succession of N2
OutputTypeSub
sub-blocks, see definition below
457
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...