3 Command Line Reference
result in the impossibility for the receiver to track a specific signal, or may significantly in-
crease the processor load. It is recommended that the product of
TpPLL
(in milliseconds) and
PLLBandwidth
(in Hz) be kept between 100 and 200.
Note that decreasing the pre-detection times increases the load on the processor.
Example
COM1>
stlp, GPSL1CA, 0.20, 12, , , off <CR>
$R: stlp, GPSL1CA, 0.20, 12, , , off
TrackingLoopParameters, GPSL1CA, 0.20, 12, 100, 10, off