3 Command Line Reference
3.2.16
SBF Configuration
smrf
gmrf
setMeas3MaxRefInterval
getMeas3MaxRefInterval
MaxIntrvl
OnlyRef
msec500
sec1
sec5
sec10
sec30
sec60
RxControl: Communication > Output Settings > SBF Output > Customize
Use this command to define at which interval to encode reference epochs (i.e. full measure-
ments) into the
SBF block. Refer to the description of the
block
for a definition of the reference epochs.
When generating the
SBF block, the receiver automatically selects an optimal
interval between reference epochs. This command allows the user to define the maximum
interval allowed for his application. Setting the
MaxIntrvl
argument to
OnlyRef
forces the
receiver to only encode reference epochs in
. This will allow to decode all
epochs independently of any previous epoch, at the expense of a larger average SBF block
size.
Example
COM1>
smrf, OnlyRef<CR>
$R: smrf, OnlyRef
Meas3MaxRefInterval, OnlyRef
COM1>
214
Содержание PolaRx5TR
Страница 1: ...PolaRx5TR Reference Guide Applicable to version 5 5 0 of the Firmware ...
Страница 73: ...3 Command Line Reference Chapter 3 Command Line Reference 73 ...
Страница 108: ...3 Command Line Reference COM1 gca Ch05 CR R gca Ch05 ChannelAllocation Ch05 G01 auto 0 16000 COM1 108 ...
Страница 130: ...3 Command Line Reference COM1 gim CR R gim IonosphereModel off COM1 130 ...
Страница 147: ...3 Command Line Reference PVTMode Static StandAlone SBAS DGPS RTKFloat RTKFixed Cartesian1 COM1 147 ...
Страница 218: ...3 Command Line Reference COM1 esoc COM1 MeasEpoch CR R esoc COM1 MeasEpoch SBFOnce COM1 MeasEpoch COM1 218 ...
Страница 237: ...3 Command Line Reference COM1 237 ...
Страница 251: ...3 Command Line Reference Event type Command etime 1588343730 before 1440 after 1440 Planned Disk DiskEvent COM1 251 ...
Страница 279: ...3 Command Line Reference COM1 279 ...
Страница 294: ...4 SBF Reference Chapter 4 SBF Reference 294 ...