User Manual
User Manual
Chapter 4
Chapter 4
3) Digital display area :
A total of 5 LED displays, which can display the
set frequency, output frequency, various monitoring data and alarm codes,
etc.
Name
15
14
Positive and negative
indicator
light on: reverse
light off: forward
Multi-function
selection button
Stop/reset button
Display information
and return button
Running
Increment button
Decrement button
Command source
Light on: terminal control
Light off: key pad control
Running indicator
Potentiometer
Shift button
Programming
button
Current
indication
Unit indicator
Voltage
indication
Keyboard button description
Button
Function
Programming
key
Enter or exit menu level I.
Confirm key
Enter the menu interfaces level by level,
and confirm the parameter setting.
Increasing
key
Increase data or function code.
Decreasing
key
Decrease data or function code.
Menu move
selection /
monitoring
key
Select the displayed parameters in turn in the stop or
running state, and select the digit to be modified
when modifying parameters.
Running key
Start the frequency inverter in the operation panel
control mode.
Stop/Reset
key
Stop the operation when it is in the running state and
perform the reset operation when it is in the fault
state. The functions of this key are restricted by P7-02.
Multifunction
key
Perform function switch over (such as quick switch
over of command source or direction) according to
the setting of P7-01.
Potentio-
meter knob
Regulate the speed directly by panel potentiometer
when P0-03 is set to 4.
4-2 Function code modification, view instructions
Function code modification instructions
The operation panel of the inverter adopts a three-level menu structure for
parameter setting and other operations. The three levels of menu are:
function parameter group (first level menu) → function code
(second level menu) → function code setting value (third level menu).
The operation process is shown in Figure 4-2.
Status parameter
(default display)
Select the function
code group
Select the
function code
Set the value of
the function code
Level-I menu
Level-II menu
Level-III menu
Example: An example of changing the function code P3-02 from 10.00 Hz to
15.00 Hz. (black mark indicates flashing bit)
Note: When operating in a three-level menu, press the PRG or ENTER key to
return to the secondary menu. The difference between the two is: press the
ENTER key to save the set parameters and return to the second level menu,
and automatically transfer to the next function code; press the PRG key to
return directly to the second level menu, do not store the parameters, and
return to the current function code .
In the third level menu, if there is no flashing bit in the parameter, it means that
the function code cannot be modified. The possible reasons are as follows:
a) The function code is an unmodifiable parameter. Such as the actual
detection parameters, operating record parameters.
b) The function code cannot be modified in the running state, and can be
modified after it needs to be stopped.
How to view status parameters
In the stop or running state, the shift key can be used to switch between
displaying various status parameters. The function code P7-03 (operation
parameter 1), P7-04 (operation parameter 2), P7-05 (stop parameter) is
selected according to the binary bit to display whether the parameter is
displayed.
PRG
FUNC
ESC
JOG
REV
STOP
RESET
RUN
PRG
PRG
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
PRG
Enter
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
Enter
Enter
50.00
050.00
P0
P0-08
Change
parameter group
Change function
parameter selection
Change function
parameter value
PRG
Enter
Enter
Enter
PRG
PRG
PRG
Menu
level1
Menu
level2
Menu
level3
Figure 4-2 Three-level menu operation flow Chart
PRG
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
PRG
PRG
Hz
V
A
RPM
%
L/R
F/R
RUN
Enter
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
Enter
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
Enter
Hz
V
A
RPM
%
L/R
F/R
RUN
Hz
V
A
RPM
%
L/R
F/R
RUN
ENTER