Sea Recovery Ultra Whisper Rev. A
Section 3 Page 12 of 12
Sea Recovery Ultra Whisper
NEW SYSTEM INITIAL READINGS
At the time of commissioning the NEW System record the following information after one hour of continuous proper
operation of the System.
Retain this form in the Owner’s Manual for future reference and troubleshooting. This information is valuable to the
servicing technicians in providing technical support to the owner and future operators of the Ultra Whisper System.
Provide this information to service technicians when requesting technical assistance.
Serial Number: ____________________________
Check Model Number:
Ultra Whisper Compact _____ 200; _____ 300; _____ 400; _____ 500; or _____ 600
Ultra Whisper Modular _____ 200; _____ 300; _____ 400; _____ 500; or _____ 600
Name of Operator: ____________________________________________ Date: _________________________
Installer Information:
Company __________________________________________________________________________
Street Address
__________________________________________________________________________
City, State __________________________________________________________________________
Country, postal code __________________________________________________________________________
Telephone number __________________________________________________________________________
Name of Installer __________________________________________________________________________
System Power: ________ Volts AC, ________ Hz or ________ Volts DC
Feed Water Temperature: ________
°
Fahrenheit or ________
°
Celsius
Hour Meter Reading: __________ Hours
PRESSURE GAUGE READINGS:
Feed Pump Inlet Vacuum/Pressure Gauge [5] Reading: ____ - In Hg, or ____ PSI, or ____ Kg/Cm
2
Prefilter Inlet Pressure Gauge [11] Reading: ____ PSI, ____ Bar, ____KPa, or _____ Kg/Cm
2
ETD Inlet Pressure Gauge [15] Reading: ____ PSI, ____ Bar, ____KPa, or ____ Kg/Cm
2
R.O. Membrane/Vessel Assy Outlet Pressure Gauge [17] Reading: ____ PSI, ____ Bar, _____KPa, or ____ Kg/Cm
WATER FLOW METER READINGS:
Product Water Flow Meter [25]: _____ US Gallons Per Hour, or _____ Liters Per Hour
WATER QUALITY:
Feed Water Salinity: __________ ppm or Location of use: ____________________________________
Product Water Salinity: ______________ ppm
Unusual occurrences or noises: _________________________________________________________________
_______________________________________________________________________________________________
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......
Страница 299: ......