Sea Recovery Ultra Whisper Rev. A
c. POSSIBLE CAUSE: There is by-passing of the Feed Water into the Product Water due to a broken or worn
Product Water O-ring, a crack or imperfection in the High Pressure Vessel End Plug, or the R.O. Membrane
Element is damaged. Depending on the amount of by-pass the pressure gauges may read normal or may read
lower than normal.
normal reading of pressure gauges:
0
-30
10
20
30
40
50
60
70
PSI
50
150
200
250
300
0
PSI
0
200
400
600
800
1000
1200
1400
PSI
PSI
0
300
250
200
150
100
50
IN Hg
100
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
or abnormally low reading of pressure gauges:
0
-30
10
20
30
40
50
60
70
PSI
IN HG
50
100
150
200
250
300
0
PSI
0
200
400
600
800
1000
1200
1400
PSI
PSI
0
300
250
200
150
100
50
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
1) Check the condition of the two Product Water O-Rings located inside each of the two High Pressure
Vessel End Plugs. Replace the O-rings if worn, flattened, or broken.
2) Check the High Pressure Vessel End Plugs for any signs of a crack between the Product Port and the
High Pressure Port. Replace the End Plug if cracked.
3) Check the High Pressure Vessel End Plugs for any signs of irregular machining of the Product Water O-
ring grooves. Replace the end plug if the machined surface at the Product Water O-ring groove shows
signs of irregularities or imperfections.
4) Check the Product Water Tube ends of the R.O. Membrane Element. Look for imperfections where the
Product Water O-ring rests on the tube ends. Look for signs of cracks on the Product Water Tube
ends. Replace the R.O. Membrane Element if imperfections or cracks are present. Note: If the
Product Water Tube is cracked or broken at either end of the R.O. Membrane Element this is caused
by excessive pressure due to a blockage in the Product Water Line.
section 6 page 29 of 38
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......
Страница 299: ......