Sea Recovery Ultra Whisper Rev. A
Operating Amperage and Operating Pressure Will Increase if:
the Feed Water Temperature is Lower than 77º Fahrenheit / 25º Celsius.
the Feed Water Salinity is Greater than 35,000 PPM TDS (3.5% Total Dissolved Solids)
the R.O. Membrane Element becomes fouled
the R.O. Membrane Element is new and on the minus 15% side of the specifications
Operating Amperage and Operating Pressure Will Decrease if:
the Feed Water Temperature is Higher than 77º Fahrenheit / 25º Celsius.
the Feed Water Salinity is Less than 35,000 PPM TDS (3.5% Total Dissolved Solids)
the R.O. Membrane Element is new and on the plus 15% side of the specifications
By monitoring Feed Water Salinity, Temperature, and resulting System Operating Pressure it is possible to
measure and monitor the fouling of the R.O. Membrane Element over time and use.
As the feed water vane pump becomes worn from normal use it will loose flow and ability to build up pressure.
A reduction in product water production could be caused by insufficient pressure and or flow from the feed
water pump. Should the feed water pump become worn resulting in reduced pressure and or flow it may be
returned to Sea Recovery for re-build or replacement. Because of the specific matching requirements of the
wear parts and tight tolerance it is not practical to repair in the field.
SYSTEM PRESSURES:
Seawater @ 35,000 PPM & 77
°
F / 25º C. Refer to Conversion Charts & Cross Reference
Information in Section 8 of this manual
Feed Water Pump
Nominal Operating Pressure
Nominal Discharge Pressure
Developed by ETD
into ETD
at R.O. Membrane Element
Model
PSI
BAR
Kg/cm
2
kPa
PSI BAR Kg/cm
2
kPa
Ultra Whisper 200
100
6.9
7.03
690
620
42.75
43.59
4275
Ultra Whisper 300
150
10.34
10.55
1034
590
40.68
41.48
4068
Ultra Whisper 400
135
9.31
9.49
931
590
40.68
41.48
4068
Ultra Whisper 500
150
10.34
10.55
1034
650
44.82
45.70
4482
Ultra Whisper 600
175
12.07
12.30
1207
680
46.89
47.81
4689
SHUT DOWN PROCEDURE of an Ultra Whisper System:
1. Prior to Stopping the System, make a copy of and fill out completely the “Sea Recovery Ultra Whisper DAILY
OPERATION LOG SYSTEM READINGS” form, located at the end of this Section, and retain the filled in copy
for future reference.
Observe and compare the performance of the system to the previously recorded Daily Operation Log System
Readings. This allows the operator to monitor performance and spot deviations or deficiencies when they occur.
2. Additionally, prior to Stopping the System determine if the System will be stored for a period of time or if it will be
operated again soon. Failure to properly flush and or store the System will lead to premature fouling, or drying out
Section 4 page 7 of 12
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......
Страница 299: ......